Microsens MS453490M Management Guide User Manual

Page 199

Advertising
background image

C

HAPTER

8

| Spanning Tree Algorithm

Configuring Global Settings for STA

– 199 –

Default: 32768

Range: 0-61440, in steps of 4096

Options: 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672,

32768, 36864, 40960, 45056, 49152, 53248, 57344, 61440

Advanced

Path Cost Method – The path cost is used to determine the best path

between devices. The path cost method is used to determine the range

of values that can be assigned to each interface.

Long: Specifies 32-bit based values that range from 1-200,000,000.

(This is the default.)

Short: Specifies 16-bit based values that range from 1-65535.

Transmission Limit – The maximum transmission rate for BPDUs is

specified by setting the minimum interval between the transmission of

consecutive protocol messages. (Range: 1-10; Default: 3)

When the Switch Becomes Root

Hello Time – Interval (in seconds) at which the root device transmits a

configuration message.

Default: 2

Minimum: 1

Maximum: The lower of 10 or [(Max. Message Age / 2) -1]

Maximum Age – The maximum time (in seconds) a device can wait

without receiving a configuration message before attempting to

reconfigure. All device ports (except for designated ports) should

receive configuration messages at regular intervals. Any port that ages

out STA information (provided in the last configuration message)

becomes the designated port for the attached LAN. If it is a root port, a

new root port is selected from among the device ports attached to the

network. (References to “ports” in this section mean “interfaces,” which

includes both ports and trunks.)

Default: 20

Minimum: The higher of 6 or [2 x (Hello Time + 1)]

Maximum: The lower of 40 or [2 x (Forward Delay - 1)]

Forward Delay – The maximum time (in seconds) this device will wait

before changing states (i.e., discarding to learning to forwarding). This

delay is required because every device must receive information about

topology changes before it starts to forward frames. In addition, each

port needs time to listen for conflicting information that would make it

return to a discarding state; otherwise, temporary data loops might

result.

Default: 15

Minimum: The higher of 4 or [(Max. Message Age / 2) + 1]

Maximum: 30

Advertising