Troubleshooting, Problems accessing the management interface, Roubleshooting – Microsens MS453490M Management Guide User Manual

Page 955: Table 144: troubleshooting chart

Advertising
background image

– 955 –

B

T

ROUBLESHOOTING

P

ROBLEMS

A

CCESSING

THE

M

ANAGEMENT

I

NTERFACE

Table 144: Troubleshooting Chart

Symptom

Action

Cannot connect using

Telnet, web browser, or

SNMP software

◆

Be sure the switch is powered up.

◆

Check network cabling between the management station

and the switch.

◆

Check that you have a valid network connection to the

switch and that the port you are using has not been

disabled.

◆

Be sure you have configured the VLAN interface through

which the management station is connected with a valid IP

address, subnet mask and default gateway.

◆

Be sure the management station has an IP address in the

same subnet as the switch’s IP interface to which it is

connected.

◆

If you are trying to connect to the switch via the IP

address for a tagged VLAN group, your management

station, and the ports connecting intermediate switches in

the network, must be configured with the appropriate tag.

◆

If you cannot connect using Telnet, you may have

exceeded the maximum number of concurrent Telnet/SSH

sessions permitted. Try connecting again at a later time.

Cannot connect using

Secure Shell

◆

If you cannot connect using SSH, you may have exceeded

the maximum number of concurrent Telnet/SSH sessions

permitted. Try connecting again at a later time.

◆

Be sure the control parameters for the SSH server are

properly configured on the switch, and that the SSH client

software is properly configured on the management

station.

◆

Be sure you have generated both an RSA and DSA public

key on the switch, exported this key to the SSH client, and

enabled SSH service.

◆

Be sure you have set up an account on the switch for each

SSH user, including user name, authentication level, and

password.

◆

Be sure you have imported the client’s public key to the

switch (if public key authentication is used).

Cannot access the on-

board configuration

program via a serial port

connection

◆

Be sure you have set the terminal emulator program to

VT100 compatible, 8 data bits, 1 stop bit, no parity, and

the baud rate set to 115200 bps.

◆

Check that the null-modem serial cable conforms to the

pin-out connections provided in the Installation Guide.

Forgot or lost the

password

◆

Contact your local distributor.