Test cable-diagnostics, Test cable- diagnostics – Microsens MS453490M Management Guide User Manual

Page 713

Advertising
background image

C

HAPTER

27

| Interface Commands

– 713 –

test cable-

diagnostics

This command performs cable diagnostics on the specified port to diagnose

any cable faults (short, open, etc.) and report the cable length.

S

YNTAX

test cable-diagnostics interface interface

interface

ethernet unit/port

unit - Unit identifier. (Range: 1)
port - Port number. (Range: 1-10)

C

OMMAND

M

ODE

Privileged Exec

C

OMMAND

U

SAGE

◆

Cable diagnostics are performed using Digital Signal Processing (DSP)

test methods.

◆

This cable test is only accurate for cables 7 - 140 meters long.

◆

The test takes approximately 5 seconds. The switch displays the results

of the test immediately upon completion, including common cable

failures, as well as the status and approximate length of each cable

pair.

◆

Potential conditions which may be listed by the diagnostics include:

■

OK: Correctly terminated pair

■

Open: Open pair, no link partner

■

Short: Shorted pair

■

Not Supported: This message is displayed for any Fast Ethernet

ports that are linked up, or for any Gigabit Ethernet ports linked up

at a speed lower than 1000 Mbps.

■

Impedance mismatch: Terminating impedance is not in the

reference range.

◆

Ports are linked down while running cable diagnostics.

E

XAMPLE

Console#test cable-diagnostics interface ethernet 1/10

Console#show cable-diagnostics interface e 1/10

Port Type Link Status Pair A (meters) Pair B (meters) Last Update

-------- ---- ----------- ---------------- ---------------- -----------------

Eth 1/10 GE Up OK (21) OK (21) 2009-11-13 09:44:19

Console#