| Basic Administration Protocols

Link Layer Discovery Protocol

– 358 –

3.

Enable LLDP, and modify any of the timing parameters as required.

4.

Click Apply.

Figure 205: Configuring LLDP Timing Attributes

C

ONFIGURING

LLDP

I

NTERFACE

A

TTRIBUTES

Use the Administration > LLDP (Configure Interface) page to specify the

message attributes for individual interfaces, including whether messages

are transmitted, received, or both transmitted and received, whether SNMP

notifications are sent, and the type of information advertised.

CLI R

EFERENCES

"LLDP Commands" on page 883

P

ARAMETERS

These parameters are displayed:

Admin Status – Enables LLDP message transmit and receive modes

for LLDP Protocol Data Units. (Options: Tx only, Rx only, TxRx,

Disabled; Default: TxRx)

SNMP Notification – Enables the transmission of SNMP trap

notifications about LLDP and LLDP-MED changes. (Default: Enabled)
This option sends out SNMP trap notifications to designated target

stations at the interval specified by the Notification Interval in the

preceding section. Trap notifications include information about state

changes in the LLDP MIB (IEEE 802.1AB), the LLDP-MED MIB (ANSI/

TIA-1057), or vendor-specific LLDP-EXT-DOT1 and LLDP-EXT-DOT3

MIBs.
For information on defining SNMP trap destinations, see

"Specifying

Trap Managers" on page 389

.

Information about additional changes in LLDP neighbors that occur

between SNMP notifications is not transmitted. Only state changes that

exist at the time of a trap notification are included in the transmission.

An SNMP agent should therefore periodically check the value of