C

HAPTER

38

| LLDP Commands

– 885 –

D

EFAULT

S

ETTING

Holdtime multiplier: 4

TTL: 4*30 = 120 seconds

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

The time-to-live tells the receiving LLDP agent how long to retain all

information pertaining to the sending LLDP agent if it does not transmit

updates in a timely manner.

E

XAMPLE

Console(config)#lldp holdtime-multiplier 10

Console(config)#

lldp notification-

interval

This command configures the allowed interval for sending SNMP

notifications about LLDP MIB changes. Use the no form to restore the

default setting.

S

YNTAX

lldp notification-interval seconds
no lldp notification-interval

seconds - Specifies the periodic interval at which SNMP notifications

are sent. (Range: 5 - 3600 seconds)

D

EFAULT

S

ETTING

5 seconds

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

This parameter only applies to SNMP applications which use data stored

in the LLDP MIB for network monitoring or management.

Information about changes in LLDP neighbors that occur between SNMP

notifications is not transmitted. Only state changes that exist at the

time of a notification are included in the transmission. An SNMP agent

should therefore periodically check the value of

lldpStatsRemTableLastChangeTime to detect any lldpRemTablesChange

notification-events missed due to throttling or transmission loss.

E

XAMPLE

Console(config)#lldp notification-interval 30