Lldp notification-interval, Lldp notification, Interval – Microsens MS453490M Management Guide User Manual

Page 885

Advertising
background image

C

HAPTER

38

| LLDP Commands

– 885 –

D

EFAULT

S

ETTING

Holdtime multiplier: 4

TTL: 4*30 = 120 seconds

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

The time-to-live tells the receiving LLDP agent how long to retain all

information pertaining to the sending LLDP agent if it does not transmit

updates in a timely manner.

E

XAMPLE

Console(config)#lldp holdtime-multiplier 10

Console(config)#

lldp notification-

interval

This command configures the allowed interval for sending SNMP

notifications about LLDP MIB changes. Use the no form to restore the

default setting.

S

YNTAX

lldp notification-interval seconds
no lldp notification-interval

seconds - Specifies the periodic interval at which SNMP notifications

are sent. (Range: 5 - 3600 seconds)

D

EFAULT

S

ETTING

5 seconds

C

OMMAND

M

ODE

Global Configuration

C

OMMAND

U

SAGE

◆

This parameter only applies to SNMP applications which use data stored

in the LLDP MIB for network monitoring or management.

◆

Information about changes in LLDP neighbors that occur between SNMP

notifications is not transmitted. Only state changes that exist at the

time of a notification are included in the transmission. An SNMP agent

should therefore periodically check the value of

lldpStatsRemTableLastChangeTime to detect any lldpRemTablesChange

notification-events missed due to throttling or transmission loss.

E

XAMPLE

Console(config)#lldp notification-interval 30

Console(config)#

Advertising