Stopbits 527 timeout login response, Stopbits, Timeout login response – Microsens MS453490M Management Guide User Manual

Page 527

Advertising
background image

C

HAPTER

21

| System Management Commands

Line

– 527 –

supported. If you select the “auto” option, the switch will automatically

detect the baud rate configured on the attached terminal, and adjust the

speed accordingly.

E

XAMPLE

To specify 57600 bps, enter this command:

Console(config-line)#speed 57600

Console(config-line)#

stopbits

This command sets the number of the stop bits transmitted per byte. Use

the no form to restore the default setting.

S

YNTAX

stopbits {1 | 2}
no stopbits

1 - One stop bit
2 - Two stop bits

D

EFAULT

S

ETTING

1 stop bit

C

OMMAND

M

ODE

Line Configuration

E

XAMPLE

To specify 2 stop bits, enter this command:

Console(config-line)#stopbits 2

Console(config-line)#

timeout login

response

This command sets the interval that the system waits for a user to log into

the CLI. Use the no form to restore the default setting.

S

YNTAX

timeout login response [seconds]
no timeout login response

seconds - Integer that specifies the timeout interval.

(Range: 0 - 300 seconds; 0: disabled)

D

EFAULT

S

ETTING

CLI: Disabled (0 seconds)

Telnet: 300 seconds