C

HAPTER

21

| System Management Commands

Line

– 522 –

R

ELATED

C

OMMANDS

parity (523)

exec-timeout

This command sets the interval that the system waits until user input is

detected. Use the no form to restore the default.

S

YNTAX

exec-timeout [seconds]
no exec-timeout

seconds - Integer that specifies the timeout interval.

(Range: 0 - 65535 seconds; 0: no timeout)

D

EFAULT

S

ETTING

CLI: No timeout

Telnet: 10 minutes

C

OMMAND

M

ODE

Line Configuration

C

OMMAND

U

SAGE

If user input is detected within the timeout interval, the session is kept

open; otherwise the session is terminated.

This command applies to both the local console and Telnet connections.

The timeout for Telnet cannot be disabled.

Using the command without specifying a timeout restores the default

setting.

E

XAMPLE

To set the timeout to two minutes, enter this command:

Console(config-line)#exec-timeout 120

Console(config-line)#

login

This command enables password checking at login. Use the no form to

disable password checking and allow connections without a password.

S

YNTAX

login [local]
no login

local - Selects local password checking. Authentication is based on

the user name specified with the

username

command.