3.14 EC-## Feedback Option

3.14.1 EC-1# Inc. Enc. Interface

EC-10 Signal Type

Select the incremental type (A/B channel) of the encoder in use.

Find the information on the encoder data sheet.

Select [0] None if the feedback sensor is an absolute encoder

only.

Option:

Function:

[0]

None

[1]

*

RS422 (5V TTL)

[2]

Sinusoidal 1Vpp

EC-11 Resolution (PPR)

Range:

Function:

1024

*

[10 - 10000] Enter the resolution of the incremental

track, i.e. the number of pulses or periods

per revolution.

3.14.2 EC-2# Abs. Enc. Interface

EC-20 Protocol Selection

Option:

Function:

NOTE

This parameter cannot be adjusted while
the motor is running.

Select [1] HIPERFACE if the encoder is absolute

only.

Select [0] None if the feedback sensor is an

incremental encoder only.

[0]

*

None

[1]

HIPERFACE

[2]

EnDat

[4]

SSI

EC-21 Resolution (Positions/Rev)

Range:

Function:

8192

*

[4 - 131072] Select the resolution of the absolute

encoder, i.e. the number of counts per

revolution.

The value depends on setting in

EC-20 Protocol Selection.

EC-24 SSI Data Length

Range:

Function:

13

*

[13 - 25] Set the number of bits for the SSI telegram.

Choose 13 bits for single-turn encoders and 25

bits for multi-turn encoder.

EC-25 Clock Rate

Range:

Function:

260 kHz

*

[100 - 260

kHz]

Set the SSI clock rate. With long

encoder cables the clock rate must

be reduced.

EC-26 SSI Data Format

Option:

Function:

[0]

*

Gray code

[1]

Binary code Set the data format of the SSI data. Choose

between Gray or Binary format.

EC-34 HIPERFACE Baudrate

Option:

Function:

NOTE

This parameter cannot be adjusted while the
motor is running.

Select the baud rate of the attached encoder.

The parameter is only accessible when

EC-20 Protocol Selection is set to [1] HIPERFACE.

[0]

600

[1]

1200

[2]

2400

[3]

4800

[4]

*

9600

[5]

19200

[6]

38400

3.14.3 EC-6# Monitoring and App.

EC-60 Feedback Direction

Option:

Function:

NOTE

This parameter cannot be adjusted
while the motor is running.

Change the detected encoder rotation

direction without changing the wiring to

the encoder.

[0]

*

Clockwise

[1]

Counter

clockwise

EC-61 Feedback Signal Monitoring

Select which reaction the frequency converter should take in

case a faulty encoder signal is detected.

The encoder function in EC-61 Feedback Signal Monitoring is an

electrical check of the hardware circuit in the encoder system.

Option:

Function:

[0]

Disabled

[1]

*

Warning

[2]

Trip

Parameter Descriptions