2 sf-2# adv. start adjust – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 141

Advertising
background image

SF-04 Wobble Jump Frequency [Hz]

Range:

Function:

voltage warning or trip (warning/alarm 7). This

parameter can only be changed in stop-mode

SF-05 Wobble Jump Frequency [%]

Range:

Function:

0 %

*

[0 - 100 %] The jump frequency can also be expressed as

percentage of the center frequency. The

function is the same as for SF-04 Wobble

Jump Frequency [Hz].

SF-06 Wobble Jump Time

Range:

Function:

0.005 s

*

[0.005 - 5.000 s]

SF-07 Wobble Sequence Time

Range:

Function:

10 s

*

[1 - 1000 s] This parameter determines the wobble

sequence period. This parameter can only be

changed in stop-mode.

Wobble time = t

up

+ t

down

SF-08 Wobble Up/ Down Time

Range:

Function:

5 s

*

[0.1 - 1000 s] Defines the individual up- and down times

for each wobble cycle.

SF-09 Wobble Random Function

Option:

Function:

[0]

*

Off

[1]

On

SF-10 Wobble Ratio

Range:

Function:

1

*

[0.1 - 20.0] If the ratio 0.1 is selected: t

down

is 10 times

greater than t

up

.

If the ratio 10 is selected: t

up

is 10 times greater

than t

down

.

SF-11 Wobble Random Ratio Max.

Range:

Function:

10

*

[par. RS-53 - 10] Enter the maximum allowed wobble ratio.

SF-12 Wobble Random Ratio Min.

Range:

Function:

0.1

*

[0.1 - par. SF-11] Enter the minimum allowed wobble

ratio.

SF-19 Wobble Delta Freq. Scaled

Range:

Function:

0 Hz

*

[0 - 1000 Hz] Readout parameter. View the actual

wobble delta frequency after scaling has

been applied.

3.22.2 SF-2# Adv. Start Adjust

SF-20 High Starting Torque Time [s]

Range:

Function:

0.0 s

*

[0 - 60 s] High starting torque time for PM-Motor in Flux

mode without feedback.

SF-21 High Starting Torque Current [%]

Range:

Function:

100.0 %

*

[0 - 200.0 %] High starting torque current for PM-

Motor in advanced vector control and

Flux mode without feedback.

SF-22 Locked Rotor Protection

Locked Rotor Protection for PM-Motor in Flux mode without

feedback.

Option:

Function:

[0]

*

Off

[1]

On

SF-23 Locked Rotor Detection Time [s]

This parameter is available for AF-650 GP only.

Range:

Function:

0.10 s

*

[0.05 - 1 s] Locked Rotor Detection Time for PM-Motor

in Flux mode without feedback.

Parameter Descriptions

AF-650 GP Programming Guide

140

DET-618C

3

3