16 id-## drive information – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 156

Advertising
background image

4.1.16 ID-## Drive Information

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

ID-0#

ID-00

Operating hours

0 h

All set-ups

FALSE

74

Uint32

ID-01

Running Hours

0 h

All set-ups

FALSE

74

Uint32

ID-02

kWh Counter

0 kWh

All set-ups

FALSE

75

Uint32

ID-03

Power Up's

0 N/A

All set-ups

FALSE

0

Uint32

ID-04

Over Temp's

0 N/A

All set-ups

FALSE

0

Uint16

ID-05

Over Volt's

0 N/A

All set-ups

FALSE

0

Uint16

ID-06

Reset kWh Counter

[0] Do not reset

All set-ups

TRUE

-

Uint8

ID-07

Reset Running Hours Counter

[0] Do not reset

All set-ups

TRUE

-

Uint8

ID-1#

ID-10

Trending Source

0

2 set-ups

TRUE

-

Uint16

ID-11

Trending Interval

ExpressionLimit

2 set-ups

TRUE

-3

TimD

ID-12

Trigger Event

[0] False

1 set-up

TRUE

-

Uint8

ID-13

Trending Mode

[0] Trend always

2 set-ups

TRUE

-

Uint8

ID-14

Samples Before Trigger

50 N/A

2 set-ups

TRUE

0

Uint8

ID-2#

ID-20

Historic Log: Event

0 N/A

All set-ups

FALSE

0

Uint8

ID-21

Historic Log: Value

0 N/A

All set-ups

FALSE

0

Uint32

ID-22

Historic Log: Time

0 ms

All set-ups

FALSE

-3

Uint32

ID-3#

ID-30

Fault Log: Error Code

0 N/A

All set-ups

FALSE

0

Uint8

ID-31

Fault Log: Value

0 N/A

All set-ups

FALSE

0

Int16

ID-32

Fault Log: Time

0 s

All set-ups

FALSE

0

Uint32

ID-4#

ID-40

Drive Type

0 N/A

All set-ups

FALSE

0

VisStr[6]

ID-41

Power Section

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-42

Voltage

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-43

Software Version

0 N/A

All set-ups

FALSE

0

VisStr[5]

ID-44

Ordered Typecode String

0 N/A

All set-ups

FALSE

0

VisStr[40]

ID-45

Actual Typecode String

0 N/A

All set-ups

FALSE

0

VisStr[40]

ID-46

GE Product No.

0 N/A

All set-ups

FALSE

0

VisStr[8]

ID-47

Power Card Ordering No

0 N/A

All set-ups

FALSE

0

VisStr[8]

ID-48

Keypad ID Number

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-49

SW ID Control Card

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-5#

ID-50

SW ID Power Card

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-51

Drive Serial Number

0 N/A

All set-ups

FALSE

0

VisStr[10]

ID-53

Power Card Serial Number

0 N/A

All set-ups

FALSE

0

VisStr[19]

ID-59

CSIV Filename

ExpressionLimit

1 set-up

FALSE

0

VisStr[16]

ID-6#

ID-60

Option Mounted

0 N/A

All set-ups

FALSE

0

VisStr[30]

ID-61

Option SW Version

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-62

Option Ordering No

0 N/A

All set-ups

FALSE

0

VisStr[8]

ID-63

Option Serial No

0 N/A

All set-ups

FALSE

0

VisStr[18]

ID-7#

ID-70

Option in Slot A

0 N/A

All set-ups

FALSE

0

VisStr[30]

ID-71

Slot A Option SW Version

0 N/A

All set-ups

FALSE

0

VisStr[20]

ID-72

Option in Slot B

0 N/A

All set-ups

FALSE

0

VisStr[30]

ID-73

Slot B Option SW Version

0 N/A

All set-ups

FALSE

0

VisStr[20]

Parameter Lists

AF-650 GP Programming Guide

DET-618C

155

4

4

Advertising