O-35 Minimum Response Delay

Range:

Function:

10 ms

*

[1 - 10000 ms] Specify the minimum delay time

between receiving a request and

transmitting a response. This is used for

overcoming modem turnaround delays.

O-36 Max Response Delay

Range:

Function:

10001 ms

*

[11 - 10001

ms]

Specify the maximum permissible

delay time between transmitting a

request and receiving a response. If a

response from the frequency converter

is exceeding the time setting then it

will be discarded.

O-37 Max Inter-Char Delay

Range:

Function:

25.00 ms

*

[0.00 -

35.00 ms]

Specify the maximum permissible time

interval between receipt of two bytes.

This parameter activates time-out if

transmission is interrupted.

This parameter is active only when

O-30 Protocol is set to [1] Drive MC

protocol.

3.10.4 O-4# Drive MC Port Settings

Parameters to configure the standard telegram or custom
telegram for the GE drive port.

O-40 Telegram Selection

Option:

Function:

[1]

*

Standard telegram 1 Enables use of freely configurable

messages or standard messages for

the Drive port.

[100] None

[101] PPO 1

[102] PPO 2

[103] PPO 3

[104] PPO 4

[105] PPO 5

[106] PPO 6

[107] PPO 7

[108] PPO 8

[200] Custom telegram 1

Enables use of freely configurable

messages or standard messages for

the Drive port.

[202] Custom telegram 3

O-41 Parameters for Signals

Option:

Function:

[0]

*

None

This parameter contains

a list of signals available

O-41 Parameters for Signals

Option:

Function:

for selection in O-42 PCD

Write Configuration and

O-43 PCD Read Configu-

ration.

[7]

Accel Time 1

[8]

Decel Time 1

[15]

Motor Speed High Limit [Hz]

[16]

Motor Speed Low Limit [Hz]

[17]

Motor Speed High Limit [RPM]

[18]

Motor Speed Low Limit [RPM]

[40]

Torque Limiter (Driving)

[41]

Torque Limiter (Braking)

[52]

Minimum Reference

[53]

Maximum Reference

[62]

Catch up/slow Down Value

[110]

Accel Time 2

[111]

Decel Time 2

[190]

Digital & Relay Bus Control

[193]

Pulse Out #27 Bus Control

[195]

Pulse Out #29 Bus Control

[197]

Pulse Out #X30/6 Bus Control

[222]

Jog Accel/Decel Time

[223]

Quick Stop Decel Time

[515]

Readout: actual setup

[653]

Terminal 42 Output Bus Control

[663]

Terminal X30/8 Bus Control

[748]

PCD Feed Forward

[890]

Bus Jog 1 Speed

[891]

Bus Jog 2 Speed

[1201] Reference [Unit]

[1202] Reference %

[1203] Status Word

[1205] Main Actual Value [%]

[1209] Custom Readout

[1210] Power [kW]

[1211] Power [hp]

[1212] Motor Voltage

[1213] Frequency

[1214] Motor current

[1215] Frequency [%]

[1216] Torque [Nm]

[1217] Speed [RPM]

[1218] Motor Thermal

[1219] KTY sensor temperature

[1220] Motor Angle

[1221] Torque [%] High Res.

[1222] Torque [%]

[1225] Torque [Nm] High

[1230] DC Link Voltage

[1232] Brake Energy /s

[1233] Brake Energy /2 min

[1234] Heatsink Temp.