Stop delay, B-28 gain boost, Factor – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 133: B-20 release brake current, Activate brake speed [rpm

Advertising
background image

B-20 Release Brake Current

Range:

Function:

par.

DR-37 A

*

[0 - par.

DR-37 A]

Set the motor current for release of the

mechanical brake, when a start condition

is present. The default value is the

maximum current the inverter can provide

for the particular power size. The upper

limit is specified in DR-37 Drive Max.

Current.

NOTE

When Mechanical brake control
output is selected but no mechanical
brake is connected, the function will
not work by default setting due to
too low motor current.

B-21 Activate Brake Speed [RPM]

Range:

Function:

0 RPM

*

[0 - 30000

RPM]

Set the motor speed for activation of

the mechanical brake, when a stop

condition is present. The upper speed

limit is specified in H-73 Warning Speed

High.

B-22 Activate Brake Speed [Hz]

Range:

Function:

0 Hz

*

[0 - 5000.0 Hz] Set the motor frequency for activation of

the mechanical brake, when a stop

condition is present.

B-23 Activate Brake Delay

Range:

Function:

0 s

*

[0 -

5 s]

Enter the brake delay time of the coast after decel

time. The shaft is held at zero speed with full

holding torque. Ensure that the mechanical brake

has locked the load before the motor enters coast

mode.

To adjust transition of the load to the mechanical

brake, set B-23 Activate Brake Delay and B-24 Stop

Delay.

Setting of brake delay parameters does not impact

the torque. The frequency converter does not

register that mechanical brake is holding the load.

B-23 Activate Brake Delay

Range:

Function:

After setting B-23 Activate Brake Delay the torque

drops to zero in few minutes. The sudden torque

change leads to movement and noise.

B-24 Stop Delay

Range:

Function:

0 s

*

[0 - 5 s] Set the time interval from the moment when the

motor is stopped until the brake closes. This

parameter is a part of the stopping function.

B-25 Brake Release Time

Range:

Function:

0.20 s

*

[0 - 5 s] This value defines the time it takes for the

mechanical brake to open/ close. This

parameter must act as a time-out when brake

feedback is activated.

B-26 Torque Ref

Range:

Function:

0 %

*

[0 - 0 %] The value defines the torque applied against

the closed mechanical brake, before release

B-27 Torque Ramp Time

Range:

Function:

0.2 s

*

[0 - 5 s] The value defines the duration of the torque

ramp in clockwise direction.

B-28 Gain Boost Factor

Range:

Function:

1

*

[0 -

4]

When a speed PID-control is connected to the

output (flux closed loop) it must be possible to

boost the proportional gain of the control during

the Activate Brake Delay (B-23 Activate Brake Delay).

By increasing the gain, the bump when the motor

takes over the load from the brake can be reduced.

The risk of oscillation is very small due to the

relatively short duration and the low (zero) speed.

Parameter Descriptions

AF-650 GP Programming Guide

132

DET-618C

3

3

Advertising