30 stator resistance, P-30 stator resistance (rs), Rotor resistance (rr) – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 59: 3 p-3# adv. motor data

Advertising
background image

P-27 Voltage filter time const.

Range:

Function:

distort the calculated voltage and affect

the stability of the system.

3.6.3 P-3# Adv. Motor Data

Parameters for advanced motor data. The motor data in
P-30 Stator Resistance (Rs) to P-39 Motor Poles must match
the relevant motor in order to run the motor optimally.
The default settings are figures based on common motor
parameter values from normal standard motors. If the
motor parameters are not set correctly, a malfunction of
the frequency converter system may occur. If the motor
data is not known, running an Auto Tune is recommended.
See the Auto Tune section. The Auto Tune sequence will
adjust all motor parameters except the moment of inertia
of the rotor and the iron loss resistance (P-36 Iron Loss
Resistance (Rfe)
).

Illustration 3.20 Motor Equivalent Diagram for an Asynchronous

Motor

Illustration 3.21 Motor Equivalent Circuit Diagram for a PM Non

Salient Motor

P-30 Stator Resistance (Rs)

Range:

Function:

1.4000

Ohm

*

[0.0140 -

140.0000

Ohm]

Set the line to common stator resistance

value. Enter the value from a motor data

sheet or perform an Auto Tune on a

cold motor.

NOTE

For PM motors:
Auto Tune is not available.
If only line-line data are available,
divide the line-line value by 2 to
achieve the line to common
(starpoint) value. Alternatively
measure the value with an
ohmmeter, this also takes the
resistance of the cable into account.
Divide the measured value by 2 and
enter the result.

P-31 Rotor Resistance (Rr)

Range:

Function:

1.0000

Ohm

*

[0.0100 -

100.0000

Ohm]

Fine-tuning R

r

will improve shaft

performance. Set the rotor resistance value

using one of these methods:

1.

Run an Auto Tune on a cold

motor. The frequency converter

will measure the value from the

motor. All compensations are

reset to 100%.

2.

Enter the R

r

value manually.

Obtain the value from the motor

supplier.

3.

Use the R

r

default setting. The

frequency converter establishes

the setting on the basis of the

motor nameplate data.

NOTE

P-31 Rotor Resistance (Rr) will not have effect when
P-20 Motor Construction = [1] PM, non salient SPM.

P-33 Stator Leakage Reactance (X1)

Range:

Function:

4.0000

Ohm

*

[0.0400 -

400.0000

Ohm]

Set the stator leakage reactance of the

motor using one of these methods:

1.

Run an Auto Tune on a cold

motor. The frequency converter

will measure the value from the

motor.

2.

Enter the X

1

value manually.

Obtain the value from the motor

supplier.

Parameter Descriptions

AF-650 GP Programming Guide

58

DET-618C

3

3

Advertising