5 parameter set-up – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 18

Advertising
background image

Operating variable

Unit

DR-20 Motor Angle

DR-30 DC Link Voltage

V

DR-32 Brake Energy /s

kW

DR-33 Brake Energy /2 min

kW

DR-34 Heatsink Temp.

C

DR-35 Drive Thermal

%

DR-36 Drive Nominal Current

A

DR-37 Drive Max. Current

A

DR-38 Logic Controller State

DR-39 Control Card Temp.

C

DR-40 Trending Buffer Full

DR-50 External Reference

DR-51 Pulse Reference

DR-52 Feedback[Unit]

[Unit]

DR-53 Digi Pot Reference

DR-60 Digital Input

bin

DR-61 Terminal 53 Switch Setting

V

DR-62 Analog Input 53

DR-63 Terminal 54 Switch Setting

V

DR-64 Analog Input 54

DR-65 Analog Output 42 [mA]

[mA]

DR-66 Digital Output [bin]

[bin]

DR-67 Freq. Input #29 [Hz]

[Hz]

DR-68 Freq. Input #33 [Hz]

[Hz]

DR-69 Pulse Output #27 [Hz]

[Hz]

DR-70 Pulse Output #29 [Hz]

[Hz]

DR-71 Relay Output [bin]

DR-72 Counter A

DR-73 Counter B

DR-80 Fieldbus CTW 1

hex

DR-82 Fieldbus REF 1

hex

DR-84 Comm. Option STW

hex

DR-85 Drive Port CTW 1

hex

DR-86 Drive Port REF 1

hex

DR-90 Alarm Word

DR-92 Warning Word

DR-94 Ext. Status Word

Table 2.1 Measurements

Status screen I
This read-out state is standard after start-up or initiali-
zation.
Press [Info] to obtain information about the measurement
links to the displayed operating variables (1.1, 1.2, 1.3, 2
and 3).
See the operating variables shown in Illustration 2.10.

Illustration 2.10 Status screen I

Status screen II
See the operating variables (1.1, 1.2, 1.3 and 2) shown in
Illustration 2.11.
In the example, speed, motor current, motor power and
frequency are selected as variables in the first and second.

Illustration 2.11 Status screen II

Status screen III
This state displays the event and action of the Logic
Controller. For further information, see 3.19 LC-## Logic
Controller
.

Illustration 2.12 Status screen III

2.1.5 Parameter Set-Up

The frequency converter can be used for practically all
assignments, which is why the number of parameters is
quite large. The frequency converter offers a choice
between two programming modes - a Main Menu and a
Quick Menu mode.
The former provides access to all parameters. The latter
takes the user through a few parameters making it
possible to start operating the frequency converter.
Change a parameter in either Main Menu mode or Quick
Menu mode.

How to Program

AF-650 GP Programming Guide

DET-618C

17

2

2