2.1.7 Initial Commissioning

The easiest way of carrying out the initial commissioning is by pressing [Quick Menu] and following the quick set-up
procedure (read Table 2.3 from left to right). The example applies to open loop applications.

Press

Quick Start

K-01 Language

Set language

K-02 Motor Speed Unit

Set motor speed in Hz or RPM

P-02 Motor Power [HP] or P-07 Motor

Power [kW]

Set Motor nameplate power

F-05 Motor Rated Voltage

Set Nameplate voltage

F-04 Base Frequency

Set Nameplate frequency

P-03 Motor Current

Set Nameplate current

P-06 Base Speed

Set Nameplate speed in RPM

F-01 Frequency Setting 1

Set reference source

F-02 Operation Method

Select which reference site to activate

F-07 Accel Time 1

Set the accel time with reference to synchronous motor

speed, n

s

F-08 Decel Time 1

Set the decel time time with reference to synchronous

motor speed, n

s

F-10 Electronic Overload

Set motor thermal protection

F-15 Motor Speed High Limit [Hz] or

F-17 Motor Speed High Limit [RPM]

Set motor speed high limit in Hz or RPM

F-16 Motor Speed Low Limit [Hz] or

F-18 Motor Speed Low Limit [RPM]

Set motor speed low limit in Hz or RPM

H-08 Reverse Lock

Set allowed rotation direction

P-04 Auto Tune

Set desired auto tune function. Enable complete auto

tune is recommended