3.7 H-## High Perf Parameters

Parameter group related to high performance functions in
the drive.

3.7.1 H-0# High Perf Operations

Parameters to restore factory setting, configure auto reset,
fan operation, reverse lock and start mode (catch a
spinning load).

H-01 Option Detection

Selects the behaviour of the frequency converter when a change

in the option configuration is detected.

Option:

Function:

[0]

*

Protect Option

Config.

Freezes the current settings and

prevents unwanted changes when

missing or defective options are

detected.

[1]

Enable Option

Change

Changes drive settings and is used

when modifying the system configu-

ration. This Parameter setting will

return to [0] Protect Option Config.

after an Option Change.

H-02 Option Data Storage

Range:

Function:

0

*

[0 - 65535]

H-03 Restore Factory Settings

Option:

Function:

Use this parameter to specify normal

operation, to perform tests or to restore all

parameters except ID-03 Power Up's,

ID-04 Over Temp's and ID-05 Over Volt's. This

function is active only when the power is

cycled (power off-power on) to the frequency

converter.

[0]

*

Normal

operation

Select [0] Normal operation for normal

operation of the frequency converter with the

motor in the selected application.

[2]

Restore

Factory

Settings

Select [2] Restore Factory Settings to reset all

parameter values to default settings, except

for ID-03 Power Up's, ID-04 Over Temp's and

ID-05 Over Volt's. The frequency converter will

reset during the next power-up.

H-03 Restore Factory Settings will also revert to

the default setting [0] Normal operation.

H-04 Auto-Reset (Times)

Option:

Function:

Select the reset function after

tripping. Once reset, the frequency

converter can be restarted.

H-04 Auto-Reset (Times)

Option:

Function:

[0]

*

Manual reset

Select [0] Manual reset, to perform a

reset via [RESET] or via the digital

inputs.

[1]

Automatic reset x 1

Select Automatic reset x 1…x20 [1]-

[12] to perform between one and

twenty automatic resets after

tripping.

[2]

Automatic reset x 2

[3]

Automatic reset x 3

[4]

Automatic reset x 4

[5]

Automatic reset x 5

[6]

Automatic reset x 6

[7]

Automatic reset x 7

[8]

Automatic reset x 8

[9]

Automatic reset x 9

[10]

Automatic reset x 10

[11]

Automatic reset x 15

[12]

Automatic reset x 20

[13]

Infinite auto reset

Select [13] Infinite Automatic Reset for

continuous resetting after tripping.

NOTE

The motor may start without warning. If the specified
number of AUTOMATIC RESETs is reached within 10
minutes, the frequency converter enters Manual reset [0]
mode. After the Manual reset is performed, the setting of
H-04 Auto-Reset (Times) reverts to the original selection. If
the number of automatic resets is not reached within 10
minutes, or when a Manual reset is performed, the internal
AUTOMATIC RESET counter returns to zero.

H-05 Auto-Reset (Reset Interval)

Range:

Function:

10 s

*

[0 - 600 s] Enter the time interval from trip to start of

the automatic reset function. This parameter

is active when H-04 Auto-Reset (Times) is set

to [1] - [13] Automatic reset.

H-07 Accel/Decel Time 1 Type

Option:

Function:

Select the ramp type, depending on

requirements for acceleration/deceleration.

A linear ramp will give constant acceleration

during ramping. An S-ramp will give non-

linear acceleration, compensating for jerk in

the application.

[0]

*

Linear

[1]

S-ramp Const

Jerk

Acceleration with lowest possible jerk.

[2]

S-ramp Const

Time

S-ramp based on the values set in F-07 Accel

Time 1 and F-08 Decel Time 1.

Parameter Descriptions

AF-650 GP Programming Guide

60