DR-72 Counter A

Range:

Function:

0

*

[-2147483648 -

2147483647]

View the present value of Counter A.

Counters are useful as comparator

operands, see LC-10 Comparator Operand.

The value can be reset or changed either

via digital inputs (parameter group E-##

Digital Inputs) or by using an LC action

(LC-52 Logic Controller Action).

DR-73 Counter B

Range:

Function:

0

*

[-2147483648 -

2147483647]

View the present value of Counter B.

Counters are useful as comparator

operands (LC-10 Comparator Operand).

The value can be reset or changed either

via digital inputs (parameter group E-0#) or

by using an Logic Controller action

(LC-52 Logic Controller Action).

DR-74 Prec. Stop Counter

Range:

Function:

0

*

[0 - 2147483647] Returns the actual counter value of

precise counter (H-84 Precise Stop Counter

Value).

DR-75 Analog In X30/11

Range:

Function:

0

*

[-20 - 20] View the actual value at input X30/11 of

OPCGPIO General Purpose I/O Option Module.

DR-76 Analog In X30/12

Range:

Function:

0

*

[-20 - 20] View the actual value at input X30/12 of

OPCGPIO General Purpose I/O Option Module.

DR-77 Analog Out X30/8 [mA]

Range:

Function:

0

*

[0 - 30]

View the actual value at input X30/8 .

3.18.6 DR-8# Fieldbus & Drive Port

Parameters to view the bus references and control words.

DR-80 Fieldbus CTW 1

Range:

Function:

0

*

[0 - 65535] View the two-byte Control word (CTW) received

from the Bus-Master. Interpretation of the

Control word depends on the Fieldbus option

installed and the Control word profile selected

in O-10 Control Word Profile.

For more information, refer to the relevant

Fieldbus manual.

DR-82 Fieldbus REF 1

Range:

Function:

0

*

[-200 - 200] View the two-byte word sent with the control

word form the Bus-Master to set the reference

value.

For more information, refer to the relevant

network manual.

DR-84 Comm. Option STW

Range:

Function:

0

*

[0 - 65535] View the extended Fieldbus comm. option

status word.

DR-85 Drive Port CTW 1

Range:

Function:

0

*

[0 - 65535] View the two-byte Control word (CTW) received

from the Bus-Master. Interpretation of the

control word depends on the Fieldbus option

installed and the Control word profile selected

in O-10 Control Word Profile.

DR-86 Drive Port REF 1

Range:

Function:

0

*

[-200 - 200] View the two-byte Status word (STW) sent to

the Bus-Master. Interpretation of the Status

word depends on the network option installed

and the Control word profile selected in

O-10 Control Word Profile.

3.18.7 DR-9# Diagnosis Readout

Parameters to view the alarms, warnings, and extended
status words.

DR-90 Alarm Word

Range:

Function:

0

*

[0 - 4294967295] View the alarm word sent via the serial

communication port in hex code.

DR-91 Alarm Word 2

Range:

Function:

0

*

[0 - 4294967295] View the alarm word sent via the serial

communication port in hex code.

DR-92 Warning Word

Range:

Function:

0

*

[0 - 4294967295] View the warning word sent via the serial

communication port in hex code.

DR-93 Warning Word 2

Range:

Function:

0

*

[0 - 4294967295] View the warning word sent via the serial

communication port in hex code.

Parameter Descriptions

AF-650 GP Programming Guide

DET-618C

117