C-21 Jog Speed [RPM]

Range:

Function:

150

RPM

*

[0 - par.

4-13 RPM]

Enter a value for the jog speed n

JOG

,

which is a fixed output speed. The

frequency converter runs at this speed

when the jog function is activated. The

maximum limit is defined in F-17 Motor

Speed High Limit [RPM].

See also C-22 Jog Accel/Decel Time.

C-22 Jog Accel/Decel Time

Range:

Function:

3.00 s

*

[0.01 -

3600 s]

Enter the jog ramp time, i.e. the acceleration/

deceleration time between 0 RPM and the

rated motor frequency n

s

. Ensure that the

resultant output current required for the given

jog ramp time does not exceed the current

limit in F-43 Current Limit. The jog ramp time

starts upon activation of a jog signal via the

keypad, a selected digital input, or the serial

communication port. When jog state is

disabled then the normal ramping times are

valid.

Illustration 3.19 Jog Ramp Time

Par

. C − 22 =

tjog

s

x

ns

RPM

Δ

log

speed

(

par

. C − 21)

RPM

C-23 Quick Stop Decel Time

Range:

Function:

3.00 s

*

[0.01 -

3600 s]

Enter the quick–stop decel time from the

synchronous motor speed to 0 RPM. Ensure

that no resultant over-voltage will arise in the

inverter due to regenerative operation of the

motor required to achieve the given decel

time. Ensure also that the generated current

required to achieve the given decel time does

not exceed the current limit (set in

F-43 Current Limit). Quick-stop is activated by

means of a signal on a selected digital input,

or via the serial communication port.

C-24 Quick Stop Ramp Type

Select the ramp type, depending on requirements for

acceleration and deceleration. A linear ramp will give constant

acceleration during ramping. An S-ramp will give non-linear

acceleration, compensating for jerk in the application.

Option:

Function:

[0]

*

Linear

[1]

S-ramp Const Jerk

[2]

S-ramp Const Time

C-25 Quick Stop S-ramp Ratio at Decel. Start

Enter the proportion of the total ramp-down time (C-23 Quick

Stop Decel Time) where the deceleration torque increases. The

larger the percentage value, the greater the jerk compensation

achieved, and thus the lower the torque jerks in the application.

Range:

Function:

50 %

*

[1 - 99 %]

C-26 Quick Stop S-ramp Ratio at Decel. End

Enter the proportion of the total ramp-down time (C-23 Quick

Stop Decel Time) where the deceleration torque decreases. The

larger the percentage value, the greater the jerk compensation

achieved, and thus the lower the torque jerks in the application.

Range:

Function:

50 %

*

[1 - 99 %]

Parameters to configure Frequency Settings 2 and 3.

C-30 Frequency Command 2

Option:

Function:

Select the reference input to be

used for the second reference

signal. F-01 Frequency Setting 1,

C-30 Frequency Command 2 and

C-34 Frequency Command 3 define

up to three different reference

signals. The sum of these reference

signals defines the actual reference.

[0]

No function

[1]

Analog Input 53

[2]

Analog Input 54

[7]

Frequency input 29

[8]

Frequency input 33

[11]

Local bus reference

[20]

*

Digital Potentiometer

[21]

Analog input X30-11

[22]

Analog input X30-12

C-34 Frequency Command 3

Option:

Function:

Select the reference input to be

used for the third reference signal.

F-01 Frequency Setting 1,

C-30 Frequency Command 2 and

C-34 Frequency Command 3 define

Parameter Descriptions

AF-650 GP Programming Guide

54