GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 123

Advertising
background image

LC-10 Comparator Operand

Array [6]

Option:

Function:

[53]

Drive ready

The frequency converter is ready for

operation and applies a supply signal

on the control board.

[54]

Running

The motor is running.

[55]

Reversing

The output is high when the

frequency converter is running

counter clockwise (the logical product

of the status bits “running” AND

“reverse”).

[56]

In range

The motor is running within the

programmed current and speed

ranges set in H-70 Warning Current

Low to H-73 Warning Speed High.

[60]

On reference

The motor is running on reference.

[61]

Below reference,

low

The motor is running below the value

given in H-74 Warning Reference Low.

[62]

Above ref, high

The motor is running above the value

given in H-75 Warning Reference High

[65]

Torque limit

The torque limit, set in F-40 Torque

Limiter (Driving) or F-41 Torque Limiter

(Braking), has been exceeded.

[66]

Current Limit

The motor current limit, set in

F-43 Current Limit, has been exceeded.

[67]

Out of current

range

The motor current is outside the

range set in F-43 Current Limit.

[68]

Below I low

The motor current is lower than set in

H-70 Warning Current Low.

[69]

Above I high

The motor current is higher than set

in H-71 Warning Current High.

[70]

Out of speed

range

The speed is outside the range set in

H-72 Warning Speed Low and

H-73 Warning Speed High.

[71]

Below speed low

The output speed is lower than the

setting in H-72 Warning Speed Low.

[72]

Above speed high

The output speed is higher than the

setting in H-73 Warning Speed High.

[75]

Out of feedback

range

The feedback is outside the range set

in H-76 Warning Feedback Low and

H-77 Warning Feedback High.

[76]

Below feedback

low

The feedback is below the limit set in

H-76 Warning Feedback Low.

[77]

Above feedback

high

The feedback is above the limit set in

H-77 Warning Feedback High.

[80]

Thermal warning

The thermal warning turns on when

the temperature exceeds the limit in

LC-10 Comparator Operand

Array [6]

Option:

Function:

the motor, the frequency converter,

the brake resistor or thermistor.

[82]

Mains out of range The mains voltage is outside the

specified voltage range.

[85]

Warning

A warning is active.

[86]

Alarm (trip)

A (trip) alarm is active.

[87]

Alarm (trip lock)

A (Trip lock) alarm is active.

[90]

Bus OK

Active communication (no time-out)

via the serial communication port.

[91]

Torque limit &

stop

If the frequency converter has

received a stop signal and is at the

torque limit, the signal is logic “0”.

[92]

Brake fault (IGBT)

The brake IGBT is short circuited.

[93]

Mech. brake

control

The mechanical brake is active.

[94]

Safe stop active

[100] Comparator 0

The result of comparator 0.

[101] Comparator 1

The result of comparator 1.

[102] Comparator 2

The result of comparator 2.

[103] Comparator 3

The result of comparator 3.

[104] Comparator 4

The result of comparator 4.

[105] Comparator 5

The result of comparator 5.

[110] Logic rule 0

The result of Logic rule 0.

[111] Logic rule 1

The result of Logic rule 1.

[112] Logic rule 2

The result of Logic rule 2.

[113] Logic rule 3

The result of Logic rule 3.

[114] Logic rule 4

The result of Logic rule 4.

[115] Logic rule 5

The result of Logic rule 5.

[120] Logic Controller

Time-out 0

The result of LC timer 0.

[121] Logic Controller

Time-out 1

The result of LC timer 1.

[122] Logic Controller

Time-out 2

The result of LC timer 2.

[123] Logic Controller

Time-out 3

The result of LC timer 3.

[124] Logic Controller

Time-out 4

The result of LC timer 4.

[125] Logic Controller

Time-out 5

The result of LC timer 5.

[126] Logic Controller

Time-out 6

The result of LC timer 6.

[127] Logic Controller

Time-out 7

The result of LC timer 7.

[130] Digital input DI18

Digital input 18. High = True.

Parameter Descriptions

AF-650 GP Programming Guide

122

DET-618C

3

3

Advertising