17 dr-## data readouts – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 157

Advertising
background image

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

ID-8#

ID-80

Fan Running Hours

0 h

All set-ups

TRUE

74

Uint32

ID-81

Preset Fan Running Hours

0 h

All set-ups

TRUE

74

Uint32

ID-9#

ID-92

Defined Parameters

0 N/A

All set-ups

FALSE

0

Uint16

ID-93

Modified Parameters

0 N/A

All set-ups

FALSE

0

Uint16

ID-98

Drive Identification

0 N/A

All set-ups

FALSE

0

VisStr[40]

ID-99

Parameter Metadata

0 N/A

All set-ups

FALSE

0

Uint16

4.1.17 DR-## Data Readouts

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

DR-0#

DR-00

Control Word

0 N/A

All set-ups

FALSE

0

V2

DR-01

Reference [Unit]

0 ReferenceFeedbackUnit

All set-ups

FALSE

-3

Int32

DR-02

Reference %

0 %

All set-ups

FALSE

-1

Int16

DR-03

Status Word

0 N/A

All set-ups

FALSE

0

V2

DR-05

Main Actual Value [%]

0 %

All set-ups

FALSE

-2

N2

DR-09

Custom Readout

0 CustomReadoutUnit

All set-ups

FALSE

-2

Int32

DR-1#

DR-10

Power [kW]

0 kW

All set-ups

FALSE

1

Int32

DR-11

Power [hp]

0 hp

All set-ups

FALSE

-2

Int32

DR-12

Motor Voltage

0 V

All set-ups

FALSE

-1

Uint16

DR-13

Frequency

0 Hz

All set-ups

FALSE

-1

Uint16

DR-14

Motor current

0 A

All set-ups

FALSE

-2

Int32

DR-15

Frequency [%]

0 %

All set-ups

FALSE

-2

N2

DR-16

Torque [Nm]

0 Nm

All set-ups

FALSE

-1

Int16

DR-17

Speed [RPM]

0 RPM

All set-ups

FALSE

67

Int32

DR-18

Motor Thermal

0 %

All set-ups

FALSE

0

Uint8

DR-19

KTY sensor temperature

0 °C

All set-ups

FALSE

100

Int16

DR-2#

DR-20

Motor Angle

0 N/A

All set-ups

TRUE

0

Uint16

DR-21

Torque [%] High Res.

0 %

All set-ups

FALSE

-1

Int16

DR-22

Torque [%]

0 %

All set-ups

FALSE

0

Int16

DR-25

Torque [Nm] High

0 Nm

All set-ups

FALSE

-1

Int32

DR-3#

DR-30

DC Link Voltage

0 V

All set-ups

FALSE

0

Uint16

DR-32

Brake Energy /s

0 kW

All set-ups

FALSE

0

Uint32

DR-33

Brake Energy /2 min

0 kW

All set-ups

FALSE

0

Uint32

DR-34

Heatsink Temp.

0 °C

All set-ups

FALSE

100

Uint8

DR-35

Drive Thermal

0 %

All set-ups

FALSE

0

Uint8

DR-36

Drive Nominal Current

ExpressionLimit

All set-ups

FALSE

-2

Uint32

DR-37

Drive Max. Current

ExpressionLimit

All set-ups

FALSE

-2

Uint32

DR-38

Logic Controller State

0 N/A

All set-ups

FALSE

0

Uint8

DR-39

Control Card Temp.

0 °C

All set-ups

FALSE

100

Uint8

DR-4#

DR-40

Trending Buffer Full

[0] No

All set-ups

TRUE

-

Uint8

DR-41

Keypad Bottom Statusline

0 N/A

All set-ups

TRUE

0

VisStr[50]

DR-48

Speed Ref. After Ramp [RPM]

0 RPM

All set-ups

FALSE

67

Int32

Parameter Lists

AF-650 GP Programming Guide

156