7 h-## high perf parameters – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 147

Advertising
background image

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

P-10

Slip Compensation Time Constant

ExpressionLimit

All set-ups

TRUE

-2

Uint16

P-2#

P-20

Motor Construction

[0] Asynchron

All set-ups

FALSE

-

Uint8

P-24

Damping Gain

140 %

All set-ups

TRUE

0

Int16

P-25

Low Speed Filter Time Const.

ExpressionLimit

All set-ups

TRUE

-2

Uint16

P-26

High Speed Filter Time Const.

ExpressionLimit

All set-ups

TRUE

-2

Uint16

P-27

Voltage filter time const.

ExpressionLimit

All set-ups

TRUE

-3

Uint16

P-3#

P-30

Stator Resistance (Rs)

ExpressionLimit

All set-ups

FALSE

-4

Uint32

P-31

Rotor Resistance (Rr)

ExpressionLimit

All set-ups

FALSE

-4

Uint32

P-33

Stator Leakage Reactance (X1)

ExpressionLimit

All set-ups

FALSE

-4

Uint32

P-34

Rotor Leakage Reactance (X2)

ExpressionLimit

All set-ups

FALSE

-4

Uint32

P-35

Main Reactance (Xh)

ExpressionLimit

All set-ups

FALSE

-4

Uint32

P-36

Iron Loss Resistance (Rfe)

ExpressionLimit

All set-ups

FALSE

-3

Uint32

P-37

d-axis Inductance (Ld)

ExpressionLimit

All set-ups

FALSE

-6

Int32

P-4#

P-46

Position Detection Gain

100 %

All set-ups

TRUE

0

Uint16

4.1.7 H-## High Perf Parameters

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

H-0#

H-01

Option Detection

[0] Protect Option Config.

1 set-up

TRUE

-

Uint8

H-02

Option Data Storage

0 N/A

2 set-ups

TRUE

0

Uint16

H-03

Restore Factory Settings

[0] Normal operation

All set-ups

TRUE

-

Uint8

H-04

Auto-Reset (Times)

[0] Manual reset

All set-ups

TRUE

-

Uint8

H-05

Auto-Reset (Reset Interval)

ExpressionLimit

All set-ups

TRUE

0

Uint16

H-07

Accel/Decel Time 1 Type

[0] Linear

All set-ups

TRUE

-

Uint8

H-08

Reverse Lock

[0] Clockwise

All set-ups

FALSE

-

Uint8

H-09

Start Mode

ExpressionLimit

All set-ups

FALSE

-

Uint8

H-2#

H-20

Motor Feedback Loss Function

[2] Trip

All set-ups

TRUE

-

Uint8

H-21

Motor Feedback Speed Error

300 RPM

All set-ups

TRUE

67

Uint16

H-22

Motor Feedback Loss Timeout

0.05 s

All set-ups

TRUE

-2

Uint16

H-24

Tracking Error Function

ExpressionLimit

All set-ups

TRUE

-

Uint8

H-25

Tracking Error

10 RPM

All set-ups

TRUE

67

Uint16

H-26

Tracking Error Timeout

1 s

All set-ups

TRUE

-2

Uint16

H-27

Tracking Error Ramping

100 RPM

All set-ups

TRUE

67

Uint16

H-28

Tracking Error Ramping Timeout

1 s

All set-ups

TRUE

-2

Uint16

H-29

Tracking Error After Ramping Timeout

5 s

All set-ups

TRUE

-2

Uint16

H-4#

H-40

Configuration Mode

ExpressionLimit

All set-ups

TRUE

-

Uint8

H-41

Motor Control Principle

ExpressionLimit

All set-ups

FALSE

-

Uint8

H-42

Flux Motor Feedback Source

[1] 24V encoder

All set-ups

FALSE

-

Uint8

H-43

Torque Characteristics

[0] Constant torque

All set-ups

TRUE

-

Uint8

H-44

Constant or Variable Torque OL

[0] High torque

All set-ups

FALSE

-

Uint8

H-45

Local Mode Configuration

[2] As mode par H-40

All set-ups

TRUE

-

Uint8

H-46

Back EMF at 1000 RPM

ExpressionLimit

All set-ups

FALSE

0

Uint16

H-47

Motor Angle Offset

0 N/A

All set-ups

FALSE

0

Int16

Parameter Lists

AF-650 GP Programming Guide

146

DET-618C

4

4