4.1.20 PI-## PID Controls

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

PI-0#

PI-00

Speed PID Feedback Source

ExpressionLimit

All set-ups

FALSE

-

Uint8

PI-02

Speed PID Proportional Gain

ExpressionLimit

All set-ups

TRUE

-4

Uint32

PI-03

Speed PID Integral Time

ExpressionLimit

All set-ups

TRUE

-4

Uint32

PI-04

Speed PID Differentiation Time

ExpressionLimit

All set-ups

TRUE

-4

Uint16

PI-05

Speed PID Diff. Gain Limit

5 N/A

All set-ups

TRUE

-1

Uint16

PI-06

Speed PID Lowpass Filter Time

ExpressionLimit

All set-ups

TRUE

-4

Uint16

PI-07

Speed PID Feedback Gear Ratio

1 N/A

All set-ups

FALSE

-4

Uint32

PI-08

Speed PID Feed Forward Factor

0 %

All set-ups

FALSE

0

Uint16

PI-09

Speed PID Error Correction w/ Ramp

300 RPM

All set-ups

TRUE

67

Uint32

PI-1#

PI-12

Torque PI Proportional Gain

100 %

All set-ups

TRUE

0

Uint16

PI-13

Torque PI Integration Time

0.020 s

All set-ups

TRUE

-3

Uint16

PI-2#

PI-20

Process CL Feedback 1 Resource

[0] No function

All set-ups

TRUE

-

Uint8

PI-22

Process CL Feedback 2 Resource

[0] No function

All set-ups

TRUE

-

Uint8

PI-3#

PI-30

Process PID Normal/ Inverse Control

[0] Normal

All set-ups

TRUE

-

Uint8

PI-31

Process PID Anti Windup

[1] On

All set-ups

TRUE

-

Uint8

PI-32

Process PID Start Speed

0 RPM

All set-ups

TRUE

67

Uint16

PI-33

Process PID Proportional Gain

0.01 N/A

All set-ups

TRUE

-2

Uint16

PI-34

Process PID Integral Time

10000 s

All set-ups

TRUE

-2

Uint32

PI-35

Process PID Differentiation Time

0 s

All set-ups

TRUE

-2

Uint16

PI-36

Process PID Diff. Gain Limit

5 N/A

All set-ups

TRUE

-1

Uint16

PI-38

Process PID Feed Forward Factor

0 %

All set-ups

TRUE

0

Uint16

PI-39

On Reference Bandwidth

5 %

All set-ups

TRUE

0

Uint8

PI-4#

PI-40

Process PID I-part Reset

[0] No

All set-ups

TRUE

-

Uint8

PI-41

Process PID Output Neg. Clamp

-100 %

All set-ups

TRUE

0

Int16

PI-42

Process PID Output Pos. Clamp

100 %

All set-ups

TRUE

0

Int16

PI-43

Process PID Gain Scale at Min. Ref.

100 %

All set-ups

TRUE

0

Int16

PI-44

Process PID Gain Scale at Max. Ref.

100 %

All set-ups

TRUE

0

Int16

PI-45

Process PID Feed Fwd Resource

[0] No function

All set-ups

TRUE

-

Uint8

PI-46

Process PID Feed Fwd Normal/ Inv. Ctrl.

[0] Normal

All set-ups

TRUE

-

Uint8

PI-49

Process PID Output Normal/ Inv. Ctrl.

[0] Normal

All set-ups

TRUE

-

Uint8

PI-5#

PI-50

Process PID Extended PID

[1] Enabled

All set-ups

TRUE

-

Uint8

PI-51

Process PID Feed Fwd Gain

1 N/A

All set-ups

TRUE

-2

Uint16

PI-52

Process PID Feed Fwd Ramp up

0.01 s

All set-ups

TRUE

-2

Uint32

PI-53

Process PID Feed Fwd Ramp down

0.01 s

All set-ups

TRUE

-2

Uint32

PI-56

Process PID Ref. Filter Time

0.001 s

All set-ups

TRUE

-3

Uint16

PI-57

Process PID Fb. Filter Time

0.001 s

All set-ups

TRUE

-3

Uint16

PI-6#

PI-60

Process PID Error

0 %

All set-ups

FALSE

-1

Int16

PI-61

Process PID Output

0 %

All set-ups

FALSE

-1

Int16

PI-62

Process PID Clamped Output

0 %

All set-ups

FALSE

-1

Int16

PI-63

Process PID Gain Scaled Output

0 %

All set-ups

FALSE

-1

Int16