4 e-## digital in/outs – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 145

Advertising
background image

4.1.4 E-## Digital In/Outs

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

E-0#

E-00

Digital I/O Mode

[0] PNP

All set-ups

FALSE

-

Uint8

E-01

Terminal 18 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-02

Terminal 19 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-03

Terminal 27 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-04

Terminal 29 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-05

Terminal 32 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-06

Terminal 33 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-07

Terminal 37 Safe Stop

[1] Safe Stop Alarm

1 set-up

TRUE

-

Uint8

E-1#

E-10

Accel Time 2

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-11

Decel Time 2

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-12

Accel Time 3

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-13

Decel Time 3

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-14

Accel Time 4

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-15

Decel Time 4

ExpressionLimit

All set-ups

TRUE

-2

Uint32

E-2#

E-20

Terminal 27 Digital Output

[0] No operation

All set-ups

TRUE

-

Uint8

E-21

Terminal 29 Digital Output

[0] No operation

All set-ups

TRUE

-

Uint8

E-24

Function Relay

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-26

On Delay, Relay

0.01 s

All set-ups

TRUE

-2

Uint16

E-27

Off Delay, Relay

0.01 s

All set-ups

TRUE

-2

Uint16

E-5#

E-51

Terminal 27 Mode

[0] Input

All set-ups

TRUE

-

Uint8

E-52

Terminal 29 Mode

[0] Input

All set-ups

TRUE

-

Uint8

E-53

Terminal X30/2 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-54

Terminal X30/3 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-55

Terminal X30/4 Digital Input

ExpressionLimit

All set-ups

TRUE

-

Uint8

E-56

Term X30/6 Digi Out (OPCGPIO)

[0] No operation

All set-ups

TRUE

-

Uint8

E-57

Term X30/7 Digi Out (OPCGPIO)

[0] No operation

All set-ups

TRUE

-

Uint8

E-6#

E-60

Term. 29 Low Frequency

100 Hz

All set-ups

TRUE

0

Uint32

E-61

Term. 29 High Frequency

100 Hz

All set-ups

TRUE

0

Uint32

E-62

Term. 29 Low Ref./Feedb. Value

0 ReferenceFeedbackUnit

All set-ups

TRUE

-3

Int32

E-63

Term. 29 High Ref./Feedb. Value

ExpressionLimit

All set-ups

TRUE

-3

Int32

E-64

Pulse Filter Time Constant #29

100 ms

All set-ups

FALSE

-3

Uint16

E-65

Term. 33 Low Frequency

100 Hz

All set-ups

TRUE

0

Uint32

E-66

Term. 33 High Frequency

100 Hz

All set-ups

TRUE

0

Uint32

E-67

Term. 33 Low Ref./Feedb. Value

0 ReferenceFeedbackUnit

All set-ups

TRUE

-3

Int32

E-68

Term. 33 High Ref./Feedb. Value

ExpressionLimit

All set-ups

TRUE

-3

Int32

E-69

Pulse Filter Time Constant #33

100 ms

All set-ups

FALSE

-3

Uint16

E-7#

E-70

Terminal 27 Pulse Output Variable

[0] No operation

All set-ups

TRUE

-

Uint8

E-72

Pulse Output Max Freq #27

5000 Hz

All set-ups

TRUE

0

Uint32

E-73

Terminal 29 Pulse Output Variable

[0] No operation

All set-ups

TRUE

-

Uint8

E-75

Pulse Output Max Freq #29

5000 Hz

All set-ups

TRUE

0

Uint32

E-76

Terminal X30/6 Pulse Output Variable

[0] No operation

All set-ups

TRUE

-

Uint8

Parameter Lists

AF-650 GP Programming Guide

144

DET-618C

4

4

Advertising