10 o-## options/comms – GE Industrial Solutions AF-650 GP General Purpose Drive Programming Guide User Manual

Page 151

Advertising
background image

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

SP-89

Decel Time 3 S-ramp Ratio at Decel. Start

50 %

All set-ups

TRUE

0

Uint8

SP-9#

SP-90

Decel Time 3 S-ramp Ratio at Decel. End

50 %

All set-ups

TRUE

0

Uint8

SP-92

Accel/Decel Ramp 4 Type

[0] Linear

All set-ups

TRUE

-

Uint8

SP-95

Accel Time 4 S-ramp Ratio at Accel. Start

50 %

All set-ups

TRUE

0

Uint8

SP-96

Accel Time 4 S-ramp Ratio at Accel. End

50 %

All set-ups

TRUE

0

Uint8

SP-97

Decel Time 4 S-ramp Ratio at Decel. Start

50 %

All set-ups

TRUE

0

Uint8

SP-98

Decel Time 4 S-ramp Ratio at Decel. End

50 %

All set-ups

TRUE

0

Uint8

4.1.10 O-## Options/Comms

Par. No.
#

Parameter description

Default value

4-set-up

Change

during

operation

Conver-

sion

index

Type

O-0#

O-01

Control Site

[0] Digital and ctrl.word

All set-ups

TRUE

-

Uint8

O-02

Control Word Source

ExpressionLimit

All set-ups

TRUE

-

Uint8

O-03

Control Word Timeout Time

1 s

1 set-up

TRUE

-1

Uint32

O-04

Control Word Timeout Function

ExpressionLimit

1 set-up

TRUE

-

Uint8

O-05

End-of-Timeout Function

[1] Resume set-up

1 set-up

TRUE

-

Uint8

O-06

Reset Control Word Timeout

[0] Do not reset

All set-ups

TRUE

-

Uint8

O-07

Diagnosis Trigger

[0] Disable

2 set-ups

TRUE

-

Uint8

O-08

Readout Filtering

ExpressionLimit

All set-ups

TRUE

-

Uint8

O-1#

O-10

Control Word Profile

[0] Drive Profile

All set-ups

TRUE

-

Uint8

O-13

Configurable Status Word STW

ExpressionLimit

All set-ups

TRUE

-

Uint8

O-14

Configurable Control Word CTW

[1] Profile default

All set-ups

TRUE

-

Uint8

O-19

Product Code

ExpressionLimit

1 set-up

TRUE

0

Uint32

O-3#

O-30

Protocol

[2] Modbus RTU

1 set-up

TRUE

-

Uint8

O-31

Address

1 N/A

1 set-up

TRUE

0

Uint8

O-32

Drive Port Baud Rate

ExpressionLimit

1 set-up

TRUE

-

Uint8

O-33

Drive Port Parity

[0] Even Parity, 1 Stop Bit

1 set-up

TRUE

-

Uint8

O-34

Estimated cycle time

0 ms

2 set-ups

TRUE

-3

Uint32

O-35

Minimum Response Delay

10 ms

All set-ups

TRUE

-3

Uint16

O-36

Max Response Delay

ExpressionLimit

1 set-up

TRUE

-3

Uint16

O-37

Max Inter-Char Delay

ExpressionLimit

1 set-up

TRUE

-5

Uint16

O-4#

O-40

Telegram Selection

[1] Standard telegram 1

2 set-ups

TRUE

-

Uint8

O-41

Parameters for Signals

0

All set-ups

FALSE

-

Uint16

O-42

PCD Write Configuration

ExpressionLimit

2 set-ups

TRUE

-

Uint16

O-43

PCD Read Configuration

ExpressionLimit

2 set-ups

TRUE

-

Uint16

O-5#

O-50

Coasting Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-51

Quick Stop Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-52

DC Brake Select

ExpressionLimit

All set-ups

TRUE

-

Uint8

O-53

Start Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-54

Reversing Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-55

Set-up Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-56

Preset Reference Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

O-57

Profidrive OFF2 Select

[3] Logic OR

All set-ups

TRUE

-

Uint8

Parameter Lists

AF-650 GP Programming Guide

150

DET-618C