VLAN Commands

switchport general acceptable-frame-type

tagged-only

Use the switchport general acceptable-frame-type tagged-only command in

Interface Configuration mode to discard untagged frames at ingress. To

enable untagged frames at ingress, use the no form of this command.

Syntax

switchport general acceptable-frame-type tagged-only
no switchport general acceptable-frame-type tagged-only

Default Configuration

All frame types are accepted at ingress.

Command Mode

Interface Configuration (gigabitethernet, port-channel, tengigabitethernet)

mode

User Guidelines

This command has no user guidelines.

Example

The following example configures 1/0/8 to discard untagged frames at ingress.

console(config)#interface gigabitethernet 1/0/8

console(config-if-1/0/8)#switchport general

acceptable-frame-type tagged-only

switchport general allowed vlan

Use the switchport general allowed vlan command in Interface

Configuration mode to add VLANs to or remove VLANs from a general port.

Syntax

switchport general allowed vlan add

vlan-list

[tagged | untagged]

2CSPC4.XModular-SWUM200.book Page 740 Thursday, March 10, 2011 11:18 AM