MAX7000_FANIN_PER_CELL
Specifies the maximum fan-in per macrocell. Legal integer values, in percentage terms, range from 20
through 100.
Old Name
Maximum Fan-in Per Macrocell -- MAX 7000B/7000AE/3000A/7000S/7000A
Type
Integer
Device Support
This setting can be used in projects targeting any Altera device family.
Notes
This assignment is included in the Analysis & Synthesis report.
This assignment supports synthesis wildcards.
Syntax
set_global_assignment -name MAX7000_FANIN_PER_CELL <value>
set_global_assignment -name MAX7000_FANIN_PER_CELL -entity <entity name>
<value>
set_instance_assignment -name MAX7000_FANIN_PER_CELL -to <to> -entity
<entity name> <value>
Default Value
100
Example
set_global_assignment -name max7000_fanin_per_cell 20
set_instance_assignment -name max7000_fanin_per_cell 20 -to foo
MNL-Q21005