OPTIMIZE_FOR_METASTABILITY

This setting improves the reliability of the design by increasing its Mean Time Between Failures (MTBF).

When this setting is enabled, the Fitter will aim to increase the output setup slacks of synchronizer

registers in the design, which can exponentially increase the design MTBF. This option takes effect only if

TimeQuest is being used for timing-driven compilation. Use the TimeQuest report_metastability

command to review the synchronizers detected in your design and to produce MTBF estimates.

Type

Enumeration

Values

• Off

• On

Device Support

This setting can be used in projects targeting any Altera device family.

Notes

This assignment is included in the Fitter report.

Syntax

set_global_assignment -name OPTIMIZE_FOR_METASTABILITY <value>

Default Value

On