FINAL_PLACEMENT_OPTIMIZATION
Specifies whether the Fitter performs final placement optimizations. Performing final placement
optimizations may improve timing and routability, but may also require longer compilation time. The
default setting of Automatically can be used with the Auto Fit Fitter Effort Level (also the default) to let
the fitter decide whether these optimizations should run based on the routability and timing requirements
of the design.
Type
Enumeration
Values
• Always
• Automatically
• Never
Device Support
This setting can be used in projects targeting any Altera device family.
Notes
This assignment is included in the Fitter report.
Syntax
set_global_assignment -name FINAL_PLACEMENT_OPTIMIZATION <value>
Default Value
Automatically