Io_maximum_toggle_rate – Altera Quartus II Settings File User Manual

Page 619

Advertising
background image

IO_MAXIMUM_TOGGLE_RATE

Specifies the toggle rate of this node. You can specify the desired frequency setting. This option is ignored

if it is applied to anything other than pins. This option can be used to direct the Fitter in its toggle-rate

checking while allowing a single-ended pin to be placed closer to a differential pin. This assignment is

used to analyze signal integrity under worst case conditions (highest possible toggle rate). A different

assignment, Power Toggle Rate, is used to specify the expected time-averaged toggle rate rather than

worst-case toggle rate, and is used by the Power Analyzer to estimate time-averaged power consumption.

Use the Synchronizer Toggle Rate if you want to configure the data rates used for Metastability Reporting

in the TimeQuest Timing Analyzer.

Old Name

TOGGLE RATE, TOGGLE_RATE

Type

Frequency

Device Support

This setting can be used in projects targeting any Altera device family.

Notes

This assignment supports Fitter wildcards.

Syntax

set_instance_assignment -name IO_MAXIMUM_TOGGLE_RATE -to <to> -entity
<entity name> <value>

MNL-Q21005

2015.05.04

IO_MAXIMUM_TOGGLE_RATE

619

Quartus Settings File Reference Manual

Altera Corporation

Send Feedback

Advertising