snmp-server sys-descr
2
snmp-server sys-descr
Sets the Management Information Base (MIB-2) object identifier (OID) system description.
Synopsis
snmp-server sys-descr string
no snmp-server sys-descr
Operands
string
The text for the system description. The string must be between 4 and
255 characters in length.
Defaults
The system description is “Brocade VDX switch”.
Command Modes
Global configuration mode
Description
Use this command to specify the MIB-2 OID description.
Usage Guidelines
Enter no snmp-server sys-descr to return to the default system description.
Examples
To set the system description OID to “Brocade Cluster switch”:
switch(config)# snmp-server sys-descr “Brocade Cluster switch”
To restore the system description OID to the default:
switch(config)# no snmp-server sys-descr
See Also
show running-config snmp-server, snmp-server community, snmp-server contact,