Sflow polling-interval (interface version) – Brocade Network OS Command Reference v4.1.0 User Manual
Page 716

678
Network OS Command Reference
53-1003115-01
sflow polling-interval (interface version)
2
sflow polling-interval (interface version)
Configures the polling interval at the interface level.
Synopsis
sflow polling-interval interval_value
no sflow polling-interval
Operands
interval_value
Specifies a value in seconds to set the polling interval. Valid values range
from 1 through 65535.
Defaults
The defaut is 20.
Command Modes
Interface subtype configuration mode
Description
Use this command to configure the polling interval for an interface. The interval is the maximum
number of seconds between successive samples of counters to be sent to the collector.
Usage Guidelines
Enter no sflow polling interval to return to the default value.
Examples
To set the polling interval to 135 seconds on a specific 40-gigabit Ethernet interface:
switch(config)# interface fortygigabitethernet 1/3/1
switch(conf-if-fo-1/3/1)# sflow polling-interval 135
See Also
interface, sflow polling-interval (global version), sflow enable (interface version),
sflow sample-rate (interface version)