diag portloopbacktest
2
Usage Guidelines
During abnormal termination, the system might be in unusable state. Perform reload to reboot the
chassis or switch to recover.
In slot-based systems, the blade under test undergoes a reset or a reinitialization sequence as
part of cleanup.
The rbridge-id is an optional parameter. If the rbridge-id is not specified, the test is assigned to the
local RBridge ID.
CAUTION
This is a disruptive command. You must disable the chassis and switch before running the test. In
addition, you must reload or fastboot the switch or chassis after the test has completed running.
Examples
In slot-based switches:
switch# diag portloopbacktest slot S1
% Info: This test should be run to completion. Please do not abort while it is
executing.
Running portloopbacktest...
<..cut..>
portLoopbackTest on ports 0-143 PASSED
portLoopbackTest on slot S1 PASSED
% Info: Resetting the blade. Please wait till it gets initialized...
In fixed-configuration switches:
switch# diag portloopbacktest
% Info: This test should be run to completion. Please do not abort while it is
executing.
Running portloopbacktest ..............
PASSED.