Show diag burninerrshow – Brocade Network OS Command Reference v4.1.0 User Manual
Page 768

730
Network OS Command Reference
53-1003115-01
show diag burninerrshow
2
show diag burninerrshow
Displays the error messages that are stored in the nonvolatile storage on the slot during the POST
and system verification processes.
Synopsis
show diag burninerrshow [rbridge-id rbridge-id]
Operands
rbridge-id rbridge-id
Specifies the RBridge ID of the switch for which errors stored in the storage
on the slot during POST and system verification are displayed.
Defaults
None
Command Modes
Privileged EXEC mode
Description
Use this command to display errors that are stored in nonvolatile storage on the slot during POST
and system verification.
Usage Guidelines
None
Examples
The error messages are updated when there is a POST failure or a systemVerification failure.
To display burn-in errors from the switch:
switch# show diag burninerrshow rbridge-id 1
errLog for slot M2
errLog is empty for slot M2
errLog for slot S1
errLog is empty for slot S1
errLog for slot S2
errLog is empty for slot S2
errLog for slot S3
errLog is empty for slot S3
errLog for slot L4
errLog is empty for slot L4
rbridgeId 1
See Also
diag burninerrclear, diag clearerror, show diag burninstatus