Lenze EVF9383 User Manual

Page 106

Advertising
background image

Control terminals
With function "Safe torque off" deactivated

5.6
5.6.4

l

5.6−8

EDSVF9383V EN 7.1−04/2012

Supply via external voltage source

GND2

+24V

+5 V

E5

A2 A3 A4 ST1ST2 59

39

3k

47k

50mA

50mA

50mA

50mA

X5 28 E1 E2 E3 E4

3k

3k

3k

3k

3k

DC 24 V

(+18 V … +30 V)

X11 K31K32 33 34

S1

+

K

SR

+

A1

X3

GND1

GND1

X6

1

2

3

4

7

7

62 63

242R

1
2
3
4
5
6

100k

100k

100k

100k

3.3nF

AIN1

AIN2

AOUTx

AOUT2

AOUT1

1

3

2

4

7

10k

10k

9300vec138

Fig. 5.6−6

Wiring of digital and analog inputs/outputs with function "Safe torque off"
deactivated, given an external voltage source

S1

Controller enable
NO contact or NC contact

Z

Load
Minimum wiring required for operation

Terminal assignment in the Lenze setting:

^ 5.6−9

)

Note!

Supplying the digital inputs via an external voltage source
enables a backup operation in the case of mains failure. After
switching off the mains voltage, all actual values are continued
to be detected and processed.

ƒ

Connect the positive pole of the external voltage source with
X5/59 to establish the backup operation in the event of mains
failure.

ƒ

The external voltage source must be able to supply a current

³ 1 A.

ƒ

The starting current of the external voltage source is not
limited by the controller. Lenze recommends the use of
voltage sources with current limitation or with an internal
impedance of Z > 1

W.