Braking operation in the network

ƒ Controllers EVF9335 ... EVF9383 in variants V270 and V300 are

equipped with an integrated brake transistor.

ƒ Controllers EVF9381 ... EVF9383 in variants V270 and V300 consist of a

master and a slave. Both master and slave contain one brake transistor,
respectively. The braking energy is normally dissipated in equal shares
via master and slave.

ƒ In the DC−bus connection you have to set the switching thresholds of

the brake transistors for all controllers of variants V270 and V300 to
the same value (C0174).

ƒ When the braking energy is low (e. g. operation in generator mode),

you can also use 9352 brake choppers. A simultaneous braking
operation with a 9352 brake chopper and an integrated brake resistor
is not possible due to the different switching thresholds.