Optimising the operating behaviour
Motor magnetising current with vector control

6.11
6.11.4

l

6.11−10

EDSVF9383V EN 7.1−04/2012

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0080 Vp field CTRL

0.50

0.00

{0.01 }

0.99 Influence on the motor

magnetising current selected
under C0095

l

Not effective with C0006 = 1
and C0025 > 1 at the same
time

l

Influence is effective from 0 Hz
to the frequency selected
under C1583

^ 6.6−1

C0095

s

Mot Io

à

0.0

{0.1 A}

1000.0 Motor magnetising current

à

dependent on C0086, C0088
and C0091

l

Change of C0086 sets C0095 to
the Lenze setting

l

Change of C0095 sets
C0086 = 0

^ 6.6−1

C1583 fset high

100.0

0

0.00

{0.01 %}

199.99 Alterations by Lenze service only!

Adaptation of the motor
magnetising current set in C0095
(with V/f characteristic control:
influence limit of the boost
correction; with vector control:
influence limit of the field
precontrol)

l

The output frequency is set up
to which the motor
magnetising current set in
C0095 is to have an effect.

l

C1583 = 100 %

¢ half the

rated motor frequency in
C0089

^
6.11−5