4 master frequency ramp-function generator (dfrfg), Master frequency ramp−function generator (dfrfg), Configuration – Lenze EVF9383 User Manual

Page 229

Advertising
background image

Configuration

Function blocks

Master frequency ramp−function generator (DFRFG)

8

8.2

8.2.4

l

8.2−13

EDSVF9383V EN 7.1−04/2012

8.2.4

Master frequency ramp−function generator (DFRFG)

The function block creates acceleration and deceleration ramps for the
operation with master frequency, thus leading the drive to the master
frequency with angular synchronism.

DFRFG1-OUT

C0764/3

DFRFG1-RESET

DFRFG1

C0764/2

C0764/1

C0760

C0759

DFRFG1-QSP

DFRFG1-STOP

C0761

C0765

C0758

DFRFG1-IN

C0752

C0754

S

R

Q

DFRFG1-FAIL

DFRFG1-SYNC

CTRL

C0753

C0751

C0755

fb_dfrfg

Fig. 8.2−9

Digital frequency ramp function generator (DFRFG1)

Codes for parameter setting

Code

Possible settings

IMPORTANT

No.

Name

Lenze Selection

C0751 DFRFG1 Tir

1.000 0.001

{0.001 s}

999.999 Acceleration time T

ir

, function

block DFRFG1

^
8.2−13

C0752 Max speed

3000 1

{1 rpm}

16000 Maximum speed, function block

DFRFG1

l

Maximum speed−up (speed)

C0753 DFRFG1 QSP

0.000 0.000

{0.001 s}

999.900 Deceleration time T

if

for quick

stop, function block DFRFG1

C0754 PH error

2

.

10

9

10

{1}

2

.

10

9

Following error, function block
DFRFG1

l

Maximum permissible phase
difference between setpoint an
actual phase

l

1 rev. = 65535 inc

C0755 Syn window

100

0

{1 inc.}

65535 Synchronisation window, function

block DFRFG1

l

1 rev. = 65535 inc

Description