background image

Distributed supply (several supply points)

10.3

l

10.3−1

EDSVF9383V EN 7.1−04/2012

10.3

Distributed supply (several supply points)

Block diagram

EVx9335

9360

EVx9321 … EVx9333

8200 vector

L1

K10

L2
L3

N
PE

F1 … F3

F7, F8

F9, F10

F11, F12

F13, F14

F4 … F6

M

3~

M

3~

M

3~

PE

PE

PE

PE

L1

L1

L1

L1

L2

L2

L2

L2

L3

L3

L3

L3

PE

PE

PE

U

U

U

V

V

V

W

W

W

BR1 BR2

+UG

+UG

+UG

-UG

+UG -UG

-UG

-UG

S2

S1

K10

K10

Z2

Z3

Z1

9300VEC200

Fig. 10.3−1

Controller with decentralised supply in the drive system

F1...F6

Mains fuses

F7 ... F14

Fuses on DC level

Z1

Mains choke

Z2

Mains choke for 9360 DC power supply units
9364: ELN3−0038H085
9365: ELN3−0017H170

Z3

DC choke
9364: 0.75 mH, 90 A
9365: 2 × 0.75 mH, 90 A (switched parallel)

K10

Mains contactor

S1

Mains "ON"

S2

Mains "OFF"