Appendix – Lenze EVF9383 User Manual

Page 454

Advertising
background image

Appendix

Index

14

14.2

l

14.2−6

EDSVF9383V EN 7.1−04/2012

Power system, 3.1−2

Protection against unexpected start−up, 11.1−1

operating mode, 11.2−2
safety relay, 3.4−1 , 11.3−1

Protection of persons, 2.3−1

with earth−leakage circuit breaker, 5.2−2

PTC motor monitoring, 6.6−8

Q

QSP (quick stop), 8.2−33 , 8.2−54

Quick stop, 6.10−4

Quick stop (QSP), 8.2−33 , 8.2−54

Quick stop deceleration time, 6.10−4 , 8.2−29 , 8.2−45 ,
8.5−11

R

Rated data, 12.2−1

for 400 V mains voltage, 3.6−1
for 500 V mains voltage, 3.6−2
integrated brake transistor, 12.3−1

Rated motor current, 6.6−1 , 6.6−16 , 6.8−9 , 8.2−44 ,
8.5−9

Rated motor frequency, 6.6−1 , 6.6−16 , 6.8−9 , 8.2−29 ,
8.2−44 , 8.5−9

Rated motor power, 6.6−1 , 6.8−8 , 8.5−8

Rated motor speed, 6.6−1 , 6.6−16 , 6.8−9 , 8.2−29 , 8.2−44
, 8.5−9

Rated motor voltage, 6.6−2 , 6.6−16 , 6.8−5 , 6.8−9 ,
8.2−29 , 8.2−44 , 8.5−9

Reaction times of digital inputs, 6.5−1

Relay output, Configuration, 6.5−3

Residual hazards, 2.3−1

Responses, 8.3−1

message, 8.3−1
TRIP, 8.3−1
warning, 8.3−1

Running optimisation, 6.11−1

S

Safe standstill, 11.1−1

Safe torque off, 11.1−1

Function deactivated, 5.6−7
functional test, 11.4−2 , 11.4−5
operating mode, 11.2−2
safety relay, 3.4−1 , 11.3−1

Safe torque offt, Function active, 5.6−4

Safety, safety engineering, 11−1

Safety engineering, 11−1

Safety function

functional test, 11.4−2 , 11.4−5
Safe torque off, 11.1−1

Safety instructions, 2−1

definition, 1.4−1
layout, 1.4−1

Safety relay, 3.4−1 , 11.3−1

− Connector X11

Terminal assignment, 11.3−2
Wiring, 11.3−2

Safety relay KSR, Terminal assignment, 5.6−9 , 11.3−2

Selecting the operating mode, speed mode, setting
acceleration and deceleration times, 6.10−3

Selection, operating mode, 6.1−1 , 6.8−1

Selection of motor type, 6.6−1 , 8.2−29 , 8.2−44 , 8.5−9

Selection of the feedback system, 6.7−1 , 8.2−42 , 8.5−4

Setting integral action component, 8.2−49

Setting the acceleration time, 6.10−3

Setting the deceleration time, 6.10−3

Setting the feedback system, 6.7−1

Setting the speed feedback, 6.7−1

Shielding

DC−bus cable, 5.4−4 , 5.5−8
motor cable, 5.4−7 , 5.5−11

Site altitude, 3.1−2

Slip compensation, 6.11−1 , 8.2−39 , 8.2−61

Speed control, 8.2−31 , 8.2−48

adapting the speed controller, 8.2−48
at vector control (MCTRL2), adapting the speed

controller, 8.2−31

− with vector control (MCTRL2)

setting integral action component, 8.2−49
speed feedback, 8.2−48
temperature detection, 8.2−49

Speed feedback, 8.2−48

Speed mode, setting acceleration and deceleration times,
6.10−3

Speed oscillations, 6.11−3

Speed setpoint limitation, 8.2−31 , 8.2−47

Speed setpoint selection, 8.2−31 , 8.2−47

Stability, of the motor, 8.2−50

Status display, keypad XT EMZ9371BC, 7.2−2

Status word AIF, 8.5−14 , 9.1−2

Stopping, 6.10−1

Advertising
This manual is related to the following products: