Configuration – Lenze EVF9383 User Manual

Page 227

Advertising
background image

Configuration

Function blocks

Master frequency output (DFOUT)

8

8.2

8.2.3

l

8.2−11

EDSVF9383V EN 7.1−04/2012

Setting: C0540 = 0

ƒ The analog signal at the input DFOUT−AN−IN is converted into a

frequency and output to X10.

ƒ Frequency calculation:

f [Hz]

+ DFOUT−AN−IN [%] @ C0030

100 @

C0011

60

Example:

The input signal at DFOUT−AN−IN amounts to 50 %, the number of
increments corresponds to 2048 inc/rev. (C0030 = 3) and the maximum
speed (C0011) is set to 3000 rpm.

f [Hz]

+ 50 % @ 2048

100 @

3000

60

+ 51200 Hz

Generating an index pulse

An artificial index signal can be generated for the output frequency.

1. Set the input DFOUT−SYN−RDY = HIGH.

– 360° later, a LOW−HIGH edge generates the index pulse.
– Then a zero pulse is generated every 360 ° according to C0030.

2. If necessary, shift the zero pulse by up to 360 ° (65536 inc = 360 °) via

C0545.

Setting: C0540 = 1

ƒ The speed signal at the input DFOUT−DF−IN is converted into a

frequency and output to X10.

ƒ Frequency calculation:

f [Hz]

+ DFOUT−DF−IN [rpm] @ C0030

60

Example:

The input signal at DFOUT−DF−IN amounts to 3000 rpm, the number of
increments corresponds to 2048 inc/revolution (C0030 = 3).

f [Hz]

+ 3000 rpm @ 2048

60

+ 102400 Hz

Generating a zero pulse

An artificial zero pulse can be generated for the output frequency.

1. Set the input DFOUT−SYN−RDY = HIGH.

– 360° later, a LOW−HIGH edge generates the zero pulse.
– Then a zero pulse is generated every 360 ° according to C0030.

2. If necessary, shift the zero pulse by up to 360 ° (65536 inc = 360 °) via

C0545.

Output of analog signal as
frequency

Output of the speed signal as
frequency

Advertising
This manual is related to the following products: