Configuration – Lenze EVF9383 User Manual

Page 272

Advertising
background image

Configuration

Function blocks
Internal motor control with vector control (MCTRL2)

8

8.2
8.2.7

l

8.2−56

EDSVF9383V EN 7.1−04/2012

Function procedure

0

1

5

2

3

4



‚

ƒ

„

C0036

9300vec089

Fig. 8.2−21

Signal sequence with DC injection braking

0 Actual speed value of the motor (e. g. MCTRL−NACT)

1 Controller output current (e. g. MCTRL−IACT)

2 Pulse inhibit (e. g. DCTRL−IMP)

3 Activating DC injection braking (MCTRL−GSB)

4 DC injection braking is active (MCTRL−GSB−OUT)

MCTRL−GSB−OUT = HIGH: Function is active
MCTRL−GSB−OUT = LOW: Function is not active

 The motor rotates with the preset speed. The current adjusts itself as a

function of the load

5.

‚ DC injection braking is activated with MCTRL−GSB = HIGH. Pulse inhibit c

is set. The motor coasts.

ƒ The pulse inhibit is deactivated and the DC braking current set in C0036 is

injected

„ DC injection braking is deactivated with MCTRL−GSB = LOW

The motor is accelerated to speed setpoint at the set acceleration ramp and
is kept there.

Advertising