Function blocks
Master frequency ramp−function generator (DFRFG)

8

8.2
8.2.4

l

8.2−16

EDSVF9383V EN 7.1−04/2012

Quick stop takes the drive out of the system and brings it to standstill.
Setpoints and actual values are continued to be detected.

t

DFRFG-IN

C0752

C0751

C0751

DFRFG-QSP

t

DFRFG-OUT

C0753

Fig. 8.2−12

Quick stop DFRFG

C0751

Acceleration and deceleration time of the profile generator

C0752

Maximum speed

C0753

Setting the deceleration time T

if

for QSP

ƒ QSP is activated using DFRFG1−QSP = HIGH.

ƒ With DFRFG1−QSP = LOW, QSP is deactivated. The setpoint is

approached via the profile generator.

The function ramp−function generator stop" keeps the state of the profile
generator during operation. Setpoints and actual values are continued to be
detected.

t

DFRFG-IN

C0752

DFRFG-STOP

t

DFRFG-OUT

Fig. 8.2−13

Ramp function generator stop

C0752

Maximum speed

ƒ The function "ramp−function generator stop" is activated with

DFRFG1−STOP = HIGH.
– The last status is output at DFRFG1−OUT.

ƒ With DFRFG1−STOP = LOW the function ramp−function generator

stop" is reset. The setpoint is approached via the profile generator.

ƒ With DFRFG1−RESET = HIGH, the profile generator is activated.

Internally added−up set phases and actual phases are reset.

ƒ The set phase is detected using a HIGH−LOW signal at DFRFG1−RESET.

Quick stop (QSP)

Ramp function generator stop

Reset ramp generator