Configuration

Code table

8

8.5

l

8.5−8

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0067 Act trip

^ Selection list 10

Momentary fault message

l

Display only

C0070 Vp speed CTRL

10.0

0.0

{0.1 }

255.9 Gain of speed controller

^
8.2−25

^
8.2−40

C0071 Tn speed CTRL

50

1

{1 ms}

6000 Integral−action time of speed

controller
C0071 = 6000 ms: No
integral−action time

C0074 limit N

10.00 0.00

{0.01 %}

100.00 Limitation of the speed controller

l

Influence of the speed
controller for V/f characteristic
control with feedback

l

max. setpoint difference in
percent

^
8.2−25

^
8.2−40

C0075 Vp curr CTRL

0.04

0.00

{0.01 }

0.99 Gain of current controller

l

Vector control: Gain of current
controller

l

V/f characteristic control:
Maximum current controller

^
8.2−25

^
8.2−40

C0076 Tn curr CTRL

10.0

0.1

{0.1 ms}

2000.0 Integral−action time of current

controller

l

Vector control: integral−action
time of current controller

l

V/f characteristic control:
maximum current controller

l

C0076 = 2000 ms: current
controller is switched off

^
8.2−25

^
8.2−40

C0077 Ti field CTRL

4.0

0.3

{0.1 ms}

6000.0 Integral−action time of field

controller

l

Only active in case of vector
control with feedback

C0078 Tn slip CTRL

100

1

{1 ms}

6000 Integral−action time of slip

controller

l

Filter time for slip
compensation (C0021)

l

Only active with V/f
characteristic control

^
8.2−25

C0079 Adapt I−CTRL

100.0

0

10.00

{0.01 %}

100.00 Adaption of the current controller

l

Evaluation for the reset time
T

ni

of the current controller

l

Effective for setpoint = 0

l

Is increased automatically to
100 % up to rated speed

l

C0079 = 100 %: no adaption of
the reset time

l

C0079 < 100 %:
– evaluation of the reset time:

^
8.2−25

^
8.2−40

C0080 Vp field CTRL

0.50

0.00

{0.01 }

0.99 Influence on the motor

magnetising current selected
under C0095

l

Not effective with C0006 = 1
and C0025 > 1 at the same
time

l

Influence is effective from 0 Hz
to the frequency selected
under C1583

^ 6.6−1

C0081

s

Mot power

à

0.01

{0.01 kW}

500.00 Rated motor power

à

Change of C0086 resets value
to factory setting

l

Change of C0081 sets C0086 =
0