Stop – Lenze EVF9383 User Manual

Page 148

Advertising
background image

Adjusting the motor
Motor temperature monitoring with PTC or thermal contact

6.6
6.6.3

l

6.6−8

EDSVF9383V EN 7.1−04/2012

Motor data

Information on the motor
nameplate

C0076

C0075

C0071

C0070

C0091

C0090

C0089

C0088

C0087

C0085

C0084

C0081

C0022

C0086

Field

T

ni

V

pi

T

nn

V

pn

cos

j

U

r

[V]

f

r

[Hz]

IN

[A]

n

N

[rpm]

L

s

[mH]

R

s

[

W]

P

r

[kW]

Imax

[A]

Type

C86

1089

MDEBAXM−080−12

252

4.16

0.95

20.69

89.00

2510

2.77

87

400

0.68

6

300

1.6

2

1090

MDEBAXM−080−32

213

3.00

0.75

11.69

65.20

1400

2.00

50

400

0.72

6

300

3.5

2

1091

MDEBAXM−080−32

253

5.20

1.30

11.69

65.20

2510

3.46

87

400

0.72

6

300

1.9

3

1092

MDEBAXM−090−12

214

4.05

1.10

6.40

37.00

1420

2.70

50

400

0.77

6

300

2.5

2

1093

MDEBAXM−090−12

254

7.05

2.00

6.40

37.00

2535

4.70

87

400

0.77

6

300

2

2

1094

MDEBAXM−090−32

215

5.40

1.50

4.80

26.00

1415

3.60

50

400

0.77

6

300

2

2

1095

MDEBAXM−090−32

255

9.30

2.70

4.80

26.00

2530

6.20

87

400

0.77

6

300

1

2

1096

MDEBAXM−100−12

216

7.20

2.20

2.90

20.00

1425

4.80

50

400

0.80

6

300

1

1.5

1097

MDEBAXM−100−12

256

12.45

3.90

2.90

20.00

2535

8.30

87

400

0.80

6

300

0.8

1.5

1098

MDEBAXM−100−32

217

9.90

3.00

2.10

17.00

1415

6.60

50

400

0.81

6

300

2.5

1.5

1099

MDEBAXM−100−32

257

17.10

5.35

2.10

17.00

2530

11.40

87

400

0.81

6

300

1.4

1.8

1100

MDEBAXM−112−22

218

12.45

4.00

1.50

11.00

1435

8.30

50

400

0.82

6

300

2

2

1101

MDEBAXM−112−22

258

21.45

7.10

1.50

11.00

2545

14.30

87

400

0.82

6

300

1

2

1102

MDEBAXM−112−32

219

17.85

5.50

2.71

21.40

1425

11.90

50

400

0.84

6

300

1.5

10

1114

MDFMAxx−200−32

224

83.25

30.00

˘

˘

1465

55.50

50

400

0.85

6

300

1

2

1115

MDFMAxx−200−32

264

145.50

52.00

˘

˘

2575

97.00

87

400

0.85

6

300

1

2

6.6.3

Motor temperature monitoring with PTC or thermal contact

PTC resistors according to DIN 44081 and DIN 44082 can be connected via
the terminal inputs T1 and T2. The motor temperature is measured and
integrated into the drive monitoring.

A thermal contact (NC contact) can also be connected to T1 and T2. Lenze
three−phase AC motors provide thermal contacts as default.

When using motors equipped with PTC resistors or thermostats, we
recommend to always activate the PTC input. This prevents the motor from
being destroyed by overheating.

(

Stop!

ƒ

The motor temperature monitoring may only be connected to
T1, T2 if the cable is terminated with a PTC or thermal contact
(NC contact) on the motor side.
– An "open" cable acts like an antenna and can cause faults on

the drive controller.

– Input signals at T1, T2 are processed with a delay of 2 s.

ƒ

The drive controller can only evaluate one PTC resistor! Do not
connect several PTC resistors in series or in parallel:
– The motor temperature would be measured incorrectly.
– The motors could be destroyed by overheating.

ƒ

If you operate several motors on a drive controller, use
thermal contacts (NC contacts) for motor temperature
monitoring and connect these in series.

ƒ

To achieve full motor protection, an additional temperature
monitoring with separate evaluation must be installed.