8.5

l

8.5−47

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0780

s

CFG: N

5250 NLIM1−OUT

^ Selection list 1

Configuration of analog input
signal, function block NSET

l

Main setpoint

See System
Manual
(extension)

C0781

s

CFG: N−INV

10251 R/L/Q−R/L

^ Selection list 2

Configuration of digital input
signal, function block NSET

l

HIGH: main setpoint (C0780) is
inverted

C0782

s

CFG: NADD

55

AIN2−OUT

^ Selection list 1

Configuration of analog input
signal, function block NSET

l

Additional setpoint

C0783

s

CFG:
NADD−INV

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block NSET

l

HIGH: additional setpoint
(C0783) is inverted

C0784

s

CFG: CINH−VAL

5001 MCTRL−NACT

^ Selection list 1

Configuration of analog input
signal, function block NSET

l

The signal is accepted by the
main setpoint integrator when
the controller is inhibited

C0785

s

CFG: SET

5000 MCTRL−nset2

^ Selection list 1

Configuration of analog input
signal, function block NSET

l

When NSET−LOAD = HIGH, the
signal is accepted by the main
setpoint integrator

C0786

s

CFG: LOAD

5001 MCTRL−QSP−OUT

^ Selection list 2

Configuration of digital input
signal, function block NSET

l

HIGH: The signal at NSET−SET is
accepted by the mains setpoint
integrator

l

Control of both ramp function
generators in special
situations, e.g. quick stop

C0787

s

^ Selection list 2

Configuration of digital input
signals, function block NSET

l

Activation of a fixed speed via
binary coding of the digital
input signals

l

For coding see description of
function block NSET

l

Parameter setting of the fixed
speeds (JOG setpoints) in
C0039

See System
Manual
(extension)

1 CFG: JOG

53

DIGIN3

NSET−JOG*1

2 CFG: JOG

1000 FIXED0

NSET−JOG*2

3 CFG: JOG

1000 FIXED0

NSET−JOG*4

4 CFG: JOG

1000 FIXED0

NSET−JOG*8

C0788

s

^ Selection list 2

Configuration of digital input
signals, function block NSET

l

Activation of additional
acceleration and deceleration
times for the mains setpoint
via binary coding of the digital
input signals

l

For coding see description of
function block NSET

l

Parameter setting of the times
in C0101 and 103

1 CFG: TI

1000 FIXED0

NSET−Ti*1

2 CFG: TI

1000 FIXED0

NSET−Ti*2

3 CFG: TI

1000 FIXED0

NSET−Ti*4

4 CFG: TI

1000 FIXED0

NSET−Ti*8