Configuration

Function blocks

Internal motor control with vector control (MCTRL2)

8

8.2

8.2.7

l

8.2−47

EDSVF9383V EN 7.1−04/2012

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0904

s

CFG: DC−BREAK

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block MCTRL

l

HIGH = Motor is braked

^
8.2−25

^
8.2−40

C0905 DIS: DC−BREAK

0

1 Function block MCTRL

l

Display of the signal linked in
C0904

C0906

−199.99

{0.01 %}

199.99 Function block MCTRL

l

Display of the signals linked in
C0890, C0891, C0892, C0893,
C0901 and C0903

^
8.2−25

^
8.2−40

1 DIS: N−SET
2 DIS: M−ADD
3 DIS: LO−M−LIM
4 DIS: HI−M−LIM
5 DIS: I−SET
6 DIS: BOOST

C0907

0

1 Function block MCTRL

l

Display of the signals linked in
C0899, C0900 and C0902

1 reserved
2 DIS: N/M−SWT
3 DIS: QSP
4 DIS: I−LOAD

C0909 speed limit

1

1

+/− 175 %

Speed limitation, function block
MCTRL

l

Limitation of direction of
rotation for the speed setpoint

^
8.2−25

^
8.2−40

2

0 ... 175 %

3

−175 ... 0 %

C0910

s

CFG: VP−ADAPT

1006 FIXED100%

^ Selection list 1

Configuration of analog input
signal, function block MCTRL

l

Gain adaptation of the speed
controller

l

If the gain is varying, join to
CURVE−OUT of FB CURVE

^
8.2−25

^
8.2−40

C0911 DIS: VP−ADAPT

−199.99

{0.01 %}

199.99 Function block MCTRL

l

Display of the signal linked in
C0910

ƒ The signal at the input MCTRL−N−SET is the setpoint speed in [%] and

always refers to the maximum speed (C0011).

ƒ In most basic configurations, MCTRL−N−SET is connected to the function

block NSET (speed setpoint conditioning).
– You can also connect MCTRL−N−SET to any other analog output signal

of a function block.

ƒ The speed setpoint at MCTRL−N−SET is always limited to ±100 % of the

maximum speed n

max

(C0011).

ƒ The motor control converts the speed setpoint into a frequency

setpoint, which is limited to a maximum output frequency, depending
on the switching frequency f

chop

Switching frequency f

chop

Maximum output frequency

2 kHz

150 Hz

4 kHz

300 Hz

Speed setpoint selection

Speed setpoint limitation

Advertising