Configuration, Code table – Lenze EVF9383 User Manual

Page 314

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−26

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.
C0425 DFIN const

3

0

256 inc/rev

Constant of the master frequency
input, function block DFIN

l

Output signal at the connected
encoder or at the upstream
controller in the event of a
master frequency
cascade/master frequency bus

^ 8.2−5

1

512 inc/rev

2

1024 inc/rev

3

2048 inc/rev

4

4096 inc/rev

5

8192 inc/rev

6

16384 inc/rev

C0426 DIS: OUT

−36000

{1 rpm}

36000 Output signal of the master

frequency input, function block
DFIN

l

Display only

C0427 DFIN function

0

Function of the master frequency
input, function block DFIN

0

2−phase

l

Phase−displaced signal
sequence

1

A pulse/B dir

l

Control of direction of rotation
via track B

2

Pulse A or B

l

Control of speed and direction
of rotation via track A or track
B

C0431

s

CFG: IN

5001 MCTRL−NACT

^ Selection list 1

Configuration of analog input
signal, function block AOUT1

l

Signal at AOUT1−IN is output to
terminal X6/62

See System
Manual
(extension)

C0432

s

CFG: OFFSET

19512 FCODE−109/1

^ Selection list 1

Configuration of offset, function
block AOUT1

l

the offset is added to the input
signal at AOUT1−IN

C0433

s

CFG: GAIN

19510 FCODE−108/1

^ Selection list 1

Configuration of gain, function
block AOUT1

l

The gain is multiplied by the
input signal at AOUT1−IN

C0434

−199.99

{0.01 %}

199.99 Function block AOUT1

l

Display of the signals linked in
C0431, C0432 and C0433

1 DIS: IN
2 DIS: OFFSET
3 DIS: GAIN

C0436

s

CFG: IN

5002 MCTRL−MSET2

^ Selection list 1

Configuration of analog input
signal, function block AOUT2

l

Signal at AOUT2−IN is output to
terminal X6/63

See System
Manual
(extension)

C0437

s

CFG: OFFSET

19513 FCODE−109/2

^ Selection list 1

Configuration of offset, function
block AOUT2

l

The offset is added to the input
signal at AOUT2−IN

C0438

s

CFG: GAIN

19511 FCODE−108/2

^ Selection list 1

Configuration of gain, function
block AOUT2

l

The gain is multiplied by the
input signal at AOUT2−IN

C0439

−199.99

{0.01 %}

199.99 Function block AOUT2

l

Display of the signals linked in
C0436, C0437 and C0438

1 DIS: IN
2 DIS: OFFSET
3 DIS: GAIN

Advertising
This manual is related to the following products: