Configuration, Code table – Lenze EVF9383 User Manual

Page 336

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−48

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0789

s

CFG: RFG−0

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block NSET

l

HIGH: Guides the main
setpoint integrator to 0 via the
current T

i

times

See System
Manual
(extension)

C0790

s

CFG: RFG−STOP

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block NSET

l

HIGH: Keeps the main setpoint
integrator on its current value

C0798

−199.99

{0.01 %}

199.99 Function block NSET

l

Display of the signals linked in
C0783 and C0785

Read only: analog input signals of
NSET

See System
Manual
(extension)

1 DIS: CINH−VAL

2 DIS: SET

C0799 Input signals

0

1 Function block NSET

l

Display of the signals linked in
C0781, C0783, C0786, C0787,
C0788, C0789 and C0790

1 DIS: N−INV
2 DIS: NADD−INV
3 DIS: LOAD
4 DIS: JOG*1
5 DIS: JOG*2
6 DIS: JOG*4
7 DIS: JOG*8
8 DIS: TI*1
9 DIS: TI*2

10 DIS: TI*4
11 DIS: TI*8
12 DIS: RFG−0
13 DIS: RFG−STOP

C0800

s

CFG: SET

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block PCTRL

l

Input for the process setpoint

l

Value range: ±200 %

See System
Manual
(extension)

C0801

s

CFG: ACT

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block PCTRL
Configuration of analog input
signal of PCTRL1

l

Input for the actual value

l

Value range:

±200 %

C0802

s

CFG: INFLU

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block PCTRL

l

Evaluation (influence) of the
output signal

l

Value range: ±200 %

C0803

s

CFG: ADAPT

1000 FIXED0%

^ Selection list 1

Configuration of analog input
signal, function block PCTRL

l

The gain V

p

can be changed via

the adaptation input

l

Value range: ±200 %

C0804

s

CFG: INACT

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block PCTRL

l

HIGH = deactivates the process
controller

C0805

s

CFG: I−OFF

1000 FIXED0

^ Selection list 2

Configuration of digital input
signal, function block PCTRL

l

HIGH = Switching off integral
action component

l

LOW = Switching on integral
action component

Advertising
This manual is related to the following products: