Configuration

Function blocks
Internal motor control with vector control (MCTRL2)

8

8.2
8.2.7

l

8.2−58

EDSVF9383V EN 7.1−04/2012

Function procedure

Automatic DC injection braking provides two function procedures, each
with a different reaction of the controller. The parameter setting is identical
for both function procedures.

Function procedure 1:

ƒ After the hold time has elapsed (C0107), the controller automatically

sets pulse inhibit

c.

0

1

5

2

3

4



‚

ƒ

„

C0107

C0036

9300vec090

Fig. 8.2−22

Signal characteristic with automatic DC injection braking

0 Speed setpoint (e. g. AIN−OUT)

1 Actual speed value of the motor (e. g. MCTRL−NACT)

2 Controller output current (e. g. MCTRL−IACT)

3 Pulse inhibit (e. g. DCTRL−IMP)

4 DC injection braking is active (MCTRL−GSB−OUT)

MCTRL−GSB−OUT = HIGH: Function is active
MCTRL−GSB−OUT = LOW: Function is not active

 The motor rotates with the preset speed. The current adjusts itself as a

function of the load

5.

‚ With a speed setpoint < speed threshold (C0019), DC injection braking is

activated. Pulse inhibit

c is set. The motor coasts.

ƒ The pulse inhibit is deactivated and the DC braking current set in C0036 is

injected

„ After the hold time (C0107) pulse inhibit c is set