Configuration, Code table – Lenze EVF9383 User Manual

Page 318

Advertising
background image

Configuration

Code table

8

8.5

l

8.5−30

EDSVF9383V EN 4.0−03/2006

IMPORTANT

Possible settings

Code

Selection

Lenze

Name

No.

C0517

v

0.00

{0.01 }

1999.00

l

The user menu contains in the
Lenze setting the most
important codes for
commissioning the operating
mode ˜V/f characteristic
control

l

With an active password
protection only the codes
entered in C0517 can be freely
accessed

l

Enter the numbers of the
required codes in the subcodes

l

The input is done in the format
xxx.yy
– xxx: Code number
– yy: Subcode number

l

It is not checked whether the
entered code exists.

1 User menu

51.00 Actual speed value (MCTRL−NACT)

2 User menu

54.00 Actual motor current (MCTRL−IACT)

3 User menu

56.00 Torque setpoint (MCTRL−MSET2)

4 User menu

64.00 Device utilisation I×t

5 User menu

183.0

0

Diagnostics

6 User menu

168.0

1

History buffer

7 User menu

39.01 JOG−setpoints 1 (NSET)

8 User menu

86.00 Motor type selection

9 User menu

148.0

0

Identifying motor parameters

10 User menu

22.00 I

max

limit in motor mode

11 User menu

23.00 I

max

limit in generator mode

12 User menu

11.00 Maximum speed N

max

13 User menu

12.00 Acceleration time T

ir

main setpoint

14 User menu

13.00 Deceleration time T

if

main setpoint

15 User menu

16.00 U

min

boost

16 User menu

70.00 Gain V

p

speed controller

17 User menu

71.00 Integral−action time T

n

speed controller

18 User menu

75.00 Gain V

p

current controller

19 User menu

76.00 Integral−action time T

n

current controller

20 User menu

142.0

0

Starting condition

21 User menu

92.00 Motor stator inductance

22 User menu

36.00 DC braking current

23 User menu

93.00 Controller identification

24 User menu

99.00 Software version

... ...

0

Not assigned

31 User menu

94.00 Password

32 User menu

3.00

Save parameter set